6.7 ALARM RECORD SETTING MENU

CH OP
1
2
3
4
5
6
7
8
9
10
12
13
14
15
16
RST
10 to 16 only valid for EDSR-1600
In ALARM RECORDING MENU, we define
(1) CH (Alarm input) : Select alarm input or RST for alarm reset input.
(2) OP (OPERATION) : ON : Records when alarm occurs.
(3) TYPE : Select alarm type:
N.C. : Normally Closed with time out function counting from alarm start
(set in DURATION)
N.C. + TRANS : Normal Closed, alarm duration as long as contacts is
active + timeout (set in DURATION)
N.O. : Normal Open with time out function counting from alarm start
(set in DURATION)
N.O. + TRANS: Normal Open, alarm duration as long as contact is
active + timeout (set in DURATION)
(4) DURATION : Timeout duration time for each event. 0~99 seconds adjustable.
Turn the JOG dial clockwise or counter-clockwise to select the options.
Press ENTER key to confirm the option and move to next column.
ENTER
Press MENU key to return to Main Menu, press again to leave Set up Menu.
MENU
ALARM SETTING MENU
TYPE DURATION
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
ON
N.O
05 SECS
N.O
OFF : No reaction when alarm occurs.