6.6 ALARM RECORD SETTING MENU
Columns in brackets () only valid for EDSR-600
In ALARM RECORDING MENU, we define
(1) CH (Alarm input) : Select alarm input or RST for alarm reset input.
(2) OP (OPERATION) : ON : Records when alarm occurs.
(3) TYPE : Select alarm type:
N.C. : Normally Closed with time out function counting from alarm start
N.C. + TRANS : Normal Closed, alarm duration as long as contacts is
N.O. : Normal Open with time out function counting from alarm start
N.O. + TRANS: Normal Open, alarm duration as long as contact is
(4) DURATION : Timeout duration time for each event. 0~99 seconds adjustable.
Turn the JOG dial clockwise or counter-clockwise to select the options.
Press ENTER key to confirm the option and move to next column.
ENTER
Press CALL key to confirm the option and move to previous column.
CALL
Press MENU key to return to Main Menu, press again to leave Set up Menu.
MENU
ALARM SETTING MENU
CH OP
TYPE DURATION
1
ON
N.O
05 SECS
2
ON
N.O
05 SECS
3
ON
N.O
05 SECS
4
ON
N.O
05 SECS
(5
ON
N.O
05 SECS)
(6.
ON
N.O
05 SECS)
RST ON
N.O
OFF : No reaction when alarm occurs.
(set in DURATION)
active + timeout (set in DURATION)
(set in DURATION)
active + timeout (set in DURATION)
16
MENU