Unit Positioning - Carrier REFRIGERANT R-410A Installation And Service Instructions Manual

Packaged air-handling units 60 hz with puron (r-410a) refrigerant sizes 25, 28, 30
Hide thumbs Also See for REFRIGERANT R-410A:
Table of Contents

Advertisement

Model Type
40RU = Carrier Fan Coil
Puronr R--- 410A Refrigerant
Type of Coil
A = Standard DX Coil
S = Chilled Water Coil
Refrigerant Options
A = None
B = Steam Coil
C = Hot Water Coil
Nominal Tonnage
25 = 20 Tons
28 = 25 Tons
30 = 30 Tons
Not Used
A = Place Holder
Indoor Fan Options
1 = Fan Drive and Motor - Low / Motor Efficiency - Standard
2 = Fan Drive and Motor - Med / Motor Efficiency - Standard
3 = Fan Drive and Motor - High / Motor Efficiency - Standard
4 = Fan Drive and Motor - Low / Motor Efficiency - Premium
5 = Fan Drive and Motor - Med / Motor Efficiency - Premium
6 = Fan Drive and Motor - High / Motor Efficiency - Premium
POSITION NUMBER
TYPICAL
Unit Positioning —
The unit can be mounted on the
floor for vertical application with return air entering the face of
the unit and supply air discharging vertically through the top of
the unit. The unit can also be applied in a horizontal
arrangement with return air entering horizontally and the
supply air discharging horizontally. When applying the unit in
a horizontal arrangement, ensure the condensate drain pan is
located at the bottom center of the unit for adequate condensate
disposal. See Fig. 5 for condensate connections for each unit
position.
Typical positioning and alternate return air locations are shown
in Fig. 5. Alternate return air locations can be used by moving
the unit panel from the alternate return air location to the
standard return air location. Refer to overhead suspension
accessory drawing (Fig. 6) for preferred suspension technique.
The unit needs support underneath to prevent sagging.
IMPORTANT: Do NOT attempt to install unit with return
air entering top panel of unit. Condensate will not drain
from unit.
1
2
3
4
5
6
7
8
4 0 R U A A 2 5 A 1 A 6
_____________
____
Fig. 3 — Model Number Nomenclature
1
2
3
4
8
0
P
O
I S
I T
O
N
1−2
3−4
5
6−10
Fig. 4 — Serial Number Nomenclature
9
10 11 12 13 14 15 16 17 18
– 0 A 0 A 0
Service Options
0 = Non-Painted Cabinet
1 = Painted Cabinet
Not Used
A = Place Holder
Not Used
0 = Place Holder
Design Rev
--- = Catalog Model Number
Voltage
1 = 575/3/60
5 = 208/ 230/3/60
6 = 460/3/60
Coil Options
A = Al/Cu
4
5
6
8
G
1
D
E
I S
G
N
A
T
E
S
W
e
k e
f o
m
a
n
f u
c a
u t
e r
i f (
c s
a
Year of manufacture ("08" = 2008)
M
a
n
u
a f
t c
r u
n i
g
o l
c
a
o i t
n
(
G
=
E
T
S
e
q
u
e
t n
a i
n l
u
m
b
r e
Accessory Line
Alternate Air Intake and Discharge
Air Intake and Discharge
Note: Maintain recommended clearances
per Figs. 2A–2B
Fig. 5 — Typical Unit Positioning
9
Brand / Packaging
0 = Standard
Not Used
A = Place Holder
7
8
9
10
2
3
4
5
c l
a
e l
n
d
a
) r
, P
e T
a x
, s
U
S
) A
LEGEND

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

40rua*2540rus*2540rua*2840rus*2840rua*3040rus*30

Table of Contents