Download Print this page
ComAp InteliVision 5 Manual

ComAp InteliVision 5 Manual

Colour 5,7" detachable display unit
Hide thumbs Also See for InteliVision 5:

Advertisement

Quick Links

InteliVision 5
SW version 2.1.0
1 General information
2 Changes in the version 2.1.0
3 Changes in the version 1.10.0
4 Changes in the version 1.9.0
5 Changes in the version 1.8.1
6 Changes in the version 1.8.0
7 Changes in the version 1.7.0
8 Changes in the version 1.6.0
9 Changes in the version 1.5.0
10 Changes in the version 1.4.0
11 Changes in the version 1.3.0
12 Changes in the version 1.2
Copyright © 2016 ComAp a.s.
Written by ComAp a.s.
Prague, Czech Republic
ComAp a.s., U Uranie 1612/14a,
170 00 Prague 7, Czech Republic
Tel: +420 246 012 111
E-mail: info@comap.cz, www.comap.cz
Colour 5,7" Detachable
3
4
5
6
7
8
9
10
11
12
13
14
New Features List
Display Unit

Advertisement

loading

Summary of Contents for ComAp InteliVision 5

  • Page 1 9 Changes in the version 1.5.0 10 Changes in the version 1.4.0 11 Changes in the version 1.3.0 12 Changes in the version 1.2 Copyright © 2016 ComAp a.s. Written by ComAp a.s. Prague, Czech Republic ComAp a.s., U Uranie 1612/14a,...
  • Page 2 13 Changes in the version 1.1.3 14 Changes in the version 1.1.1 15 Changes in the version 1.1 16 Related information 17 Notes InteliVision 5 - New Features List...
  • Page 3: General Information

    1 General information 1.1 Version information This document supplements the InteliVision 5 Reference Guide 1.2 Clarification of notation Note: This type of paragraph calls readers attention to a notice or related theme. IMPORTANT: This type of paragraph highlights a procedure, adjustment etc., which can cause a damage or improper function of the equipment if not performed correctly and may not be clear at first sight.
  • Page 4: New Features

    Repeated message new firmware available in GenConfig the issue is connected only with firmware IV5 1.10.0 the issue must be solved in GenConfig as well, the release of the GenConfig with the repaired issue is planned to Q3//2018 InteliVision 5 - New Features List...
  • Page 5 3 Changes in the version 1.10.0 3.1 New features Changes related to the InteliVision 5 CAN firmware only for more information please see the InteliVision 5 CAN NFL InteliVision 5 - New Features List...
  • Page 6 4 Changes in the version 1.9.0 4.1 New features All the new features and bugfixes have been taken over from the InteliVision 5 to the InteliVision 5 CAN display unit there is no difference between InteliVision 5 and InteliVision 5 CAN firmwares from the software point of...
  • Page 7 5 Changes in the version 1.8.1 5.1 Bug fixes Unpredictible behaviour of the setpoint listing on the InteliVision 5 display unit when the controller configuration has more than 512 parameters in all the groups (entirely). InteliVision 5 - New Features List...
  • Page 8 6.1 New features The support of the InteliSys GAS 1.2.0 if the controller has a large configuration the display unit IntelIVision 5 downloads only the actually chosen language ECU source address is displayed in the alarmlist item comming from ECU (in format ADR : number) IMPORTANT: InteliSys GAS 1.2.0 archives and newer is compatible only with the GenConfig...
  • Page 9 IMPORTANT: If the older archive is opened in GenConfig 3.6.0 and newer The aftertreatment meter (instrument) in InteliVision 5 is not supported. IMPORTANT: It is very recommended to upgrade both InteliVision 5 firmware to version 1.7.0 and controllers archives to the newest ones (as specified above) to fully support of Tier IV Final standard.
  • Page 10 8 Changes in the version 1.6.0 8.1 New features Support of inteliSys Gas controller Updated list of the connected modules IMPORTANT: The display settings (Backlite time) is lost using the upgrade from 1.5.0 to 1.6.0 InteliVision 5 - New Features List...
  • Page 11 9 Changes in the version 1.5.0 9.1 Bug fixes Forced Value can not be changed, because of incorrectly evaluated limits InteliVision 5 - New Features List...
  • Page 12 10 Changes in the version 1.4.0 10.1 New features Add support of a customer branch. Just for customer branch purpose (for standard product update is not needed). InteliVision 5 - New Features List...
  • Page 13 11 Changes in the version 1.3.0 11.1 New features Add support of a customer branch. Just for customer branch purpose (for standard product update is not needed). InteliVision 5 - New Features List...
  • Page 14 12.4 Support of new symbols for TIER 4 regulation Available in Screen Editor from incoming GC The new symbols for the support of Tier 4 regulation were added to InteliVision 5. The types of added symbols are displayed in the Types added TIER 4 symbols (page 15).
  • Page 15 IMPORTANT: Binary indicators will be available in Screen Editor form incoming GC version. 12.6 Setpoints values of Econ, INCON, and DENOX There is fixed issue with Setpoints values of ECON, INCON and DENOX. They are visible now and it is possible to edit them. InteliVision 5 - New Features List...
  • Page 16 Fixed problem with IV5 restart after IV5 wakes up from a screen saver. Fixed problem with intermittent communication drop-out when more IV5 displays is connected via NT terminal connection. Fixed problem with intermittent communication drop-out when using Direct connection to the controller. InteliVision 5 - New Features List...
  • Page 17 It enables the usage of converters with constant communication speed in both directions between InteliVision 5 and the controller. With version 1.1.1 it is possible to run InteliVision 5 connected to controller RS232 or RS485 port with following setting in the controller:...
  • Page 18 14.2 How to program InteliVision 5 For programming of new firmware, upgrade of fonts and logo download the InteliVision 5 has to be connected to any IG/IS-NT-(BB) controller to it’s NT-terminal interface, i.e. RS485(1)/display port. Then the programming is done from GenConfig tool: 1.
  • Page 19 14.3 How to connect InteliVision 5 to the controller (DIRECT connection) Option A Option C Analogical to Option A for second RS232 port InteliVision 5 - New Features List...
  • Page 20 Option D Note: Make sure that bias (pull up, pull down) resistors are connected only on one side of the RS485 line. InteliVision 5 - New Features List...
  • Page 21 14.4 How to setup InteliVision 5 for direct connection After start-up After InteliVision 5 has been programmed with version 1.1.1 or higher connect it to the controller with direct connection (see How to connect InteliVision 5 to the controller (DIRECT connection) on page 19) and switch on.
  • Page 22 Communication parameters can be changed while the InteliVision 5 is running. Go to Menu, select Help/Others and Communication. The same parameters as described in chapter After start-up appear on the screen. InteliVision 5 - New Features List...
  • Page 23 “Statictic I.” screen in Measurement. Labels on buttons are customizable. The functions can be easily defined in new graphical screen editor. Functions actually assigned to buttons in actual archives are default. InteliVision 5 - New Features List...
  • Page 24 Parameter enables/disables using of internal buzzer. The parameter is placed in “IV setting” MENU and it is available only in IV5-RD display. Default setting is enabled. Whether the buzzer should be active, it is given by the controller. If communication with the controller is lost, InteliVision 5 - New Features List...
  • Page 25 Image 9.2 Acces deniend message 15.9 Acces level indication Access level of a logged user is indicated in the upper right corner of the screen (see Access level indication on page 25). Image 9.3 Access level indication InteliVision 5 - New Features List...
  • Page 26 See texts and values on right side of Access level indication (page 25). 15.12 Deviator limits Limits of deviator and their values are displayed also in negative part of graph. InteliVision 5 - New Features List...
  • Page 27: Related Information

    16 Related information 16.1 Available files Display unit version Important note InteliVision5-2.1.0 Specific branch modification InteliVision5-1.10.0 Changes related only to InteliVision 5 CAN firmware InteliVision5-1.9.0 InteliDrive DCU Marine 3.0.0 support InteliVision5-1.8.0 InteliSys GAS 1.2.0 support InteliVision5-1.7.0 TIer IV Final support Table 10.1 Available firmware...
  • Page 28: Document History

    Ondrej Rais 1.8.0 24.4.2017 Ondrej Rais 1.7.0. 31.3.2017 Ondrej Rais 1.6.0. 22.3.2016 Ondrej Rais 1.5.0. 21.10.2015 Ondrej Rais 1.4.0. 30.3.2015 ComAp a.s. 1.2.0. 4.2.2014 ComAp a.s. 1.1.0. 25.11.2011 ComAp a.s. 1.0.0 14.1.2011 ComAp a.s. InteliVision 5 - New Features List...