VENTING WITH THREE (3) 90° ELBOWS
V (FT.)
3' MINIMUM (914 mm)
4' MINIMUM (1.2 m)
5' MINIMUM (1.6 m)
RATIO V TO H = 1:2
V + V
+ H + H
= 30' MAXIMUM (9.3m)
1
1
H + H
= 20' MAXIMUM (6.2m)
1
H = 10' MAXIMUM (3.1m)
V
1
H
1
VENTING WITH THREE (3) 90° ELBOWS
V (FT.)
3' MINIMUM (914 mm)
4' MINIMUM (1.2 m)
5' MINIMUM (1.6 m)
6' MINIMUM (1.9 m)
V + V
+ H + H
= 30' MAXIMUM (9.3 m)
1
1
H + H
= 20' MAXIMUM (6.2 m)
1
RATIO V TO H + H
= 1:2
1
Figure 9. Venting with three 90° elbows
H (FT.)
6' MAXIMUM (1.9 m)
8' MAXIMUM (2.4 m)
10' MAXIMUM (3.1 m)
H
1
NOTE: SRV570-290 Heat
Shield is required above
elbow if clearance is less
than 4 inches (102mm).
H + H
(FT.)
1
6' MAXIMUM (1.9 m)
8' MAXIMUM (2.4 m)
10' MAXIMUM (3.1 m)
12' MAXIMUM (3.6 m)
H
14
H
V
1
V
V