Clock; Shipping And Storage Conditions - Siemens SIMOTION SCOUT D410 Manual

Hide thumbs Also See for SIMOTION SCOUT D410:
Table of Contents

Advertisement

6.6

Clock

Features of real-time clock
The table below contains the features and functions of the Control Unit clock.
Table 6- 14
Features
Type
Default setting when delivered
Maximum deviation per day
with supply voltage switched on and switched off at
0 to 55° C
Backup time
Charging time
With power OFF
The Control Unit clock continues to operate with the POWER OFF for the duration of the
battery backup time (excluding software clock). The buffer is recharged in the POWER ON
state. If the real-time clock backup time is exceeded, the time is reset. If the
SIMOTION D410 is reset to its factory settings, the clock is also reset to the "default setting
when delivered".
6.7

Shipping and storage conditions

With regard to transportation and storage conditions, the control surpasses the requirements
specified in DIN EN 60068-2. The following conditions apply to modules that are transported
and stored in their original packaging.
Table 6- 15
Type of condition
Free fall, checked according to
DIN EN60721-3-2, Class 2M2
Permissible ambient temperature
during storage and transport
Air pressure
Relative humidity
D410
Manual, 05/2009
Clock features
Shipping and storage conditions
Permissible range
≤ 1 m
-40 °C to +70 °C
700 to 1060 hPa (equals a height of up to 3000 m)
5% to 95%, without condensation
Description
Hardware clock (integrated "real-time clock")
DT#1992-01-01-00:00:00
±9 s
Typically 5 days (at 0 to 25° C)
1 h
Technical data
6.6 Clock
85