  • Page 2: General Safety Instructions

    GENERAL SAFETY INSTRUCTIONS 1. Read the instructions and warning in this manual carefully, they contain important information regarding safe installation, use and maintenance. This manual is an integral part of the product. Hand it on to the next user/owner in case of change of property. 2.
  • Page 3 check valve and control, safety valve and hydraulic load cutout. 10. Do not tamper with the overpressure safety device (valve or safety group), if supplied together with the appliance; trip it from time to time to ensure that it is not jammed and to remove any scale de- posits.
  • Page 4 Symbol Meaning Failure to observe this warning can result in injury, which may even be fatal in certain circumstances Failure to observe this warning can result in damage or injury, even serious in certain circumstances, to property, plants and animals Observe the product’s general and specific safety instructions.
  • Page 5: Technical Characteristics

    LEGIONELLA BACTERIA Legionella are small rod shaped bacteria which are a natural constituent of all fresh waters. Legionaries’ disease is a pneumonia infection caused by inhaling of Legionella species. Long periods of water stag- nation should be avoided; it means the water heater should be used or flushed at least weekly. The European standard CEN/TR 16355 gives recommendations for good practice concerning the pre- vention of Legionella growth in drinking water installations but existing national regulations remain in force.
  • Page 6: Hydraulic Connection

    INSTALLING NORMS (for the installer) CAUTION: Observe all general warnings and safety standards listed at the beginning of this text in full; all such instructions are obligatory. The appliance must be installed and commissioned by a qualified technician in accordance with estab- lished regulations and local health and safety regulations.
  • Page 7 NOTE: Elements burn through commissioning without water and burnouts due to loose connections are not covered by the Warranty. For greater safety, have qualified personnel carry out a careful inspection of the electrical system, ensur- ing it complies with the applicable norms in force, because the appliance manufacturer will not be held responsible for any damage caused by the lack of earthing of the system or for faults in the electricity supply.
  • Page 8 Replacing parts Disconnect the appliance from its power supply. Remove the enclosure to access the electrical equipment. To work on the thermostat, extract it from its mount and disconnect it from its power supply. To work on the heating element and anode, first drain the appliance. Use only original spare parts Scheduled maintenance The heating element (R fig.
  • Page 9: Useful Hints

    USEFUL HINTS If the water delivery is cold, have the following checked: - is there power to the thermostat and terminal block? - are the heating elements working? If the water is boiling hot (steam is coming out of the taps) Shut off electrical power to the appliance and have the following checked: - thermostat;...
  • Page 10 10 / EN...
  • Page 11 11 / EN...
  • Page 12 12 / EN...
  • Page 13: Warranty

    Warranty in virtue of its nature of consumable material. 9. Ariston will not be held responsible for any dam- age, direct or indirect, to people, animals, prop- 5. Furthermore this Warranty will not cover: trans- erties in the house due to the non observance portation and handling damages;...
  • Page 14 14 / EN...
  • Page 15 15 / EN...
  • Page 16 Ariston Thermo SpA Ariston Thermo South Africa (Pty) Ltd Viale Aristide Merloni 45 294 Barolong St. Icon Business Park 60044 Fabriano (AN) Italy Sunderland Ridge Telefono 0732 6011 - Fax 0732 602331 South Africa info.it@aristonthermo.com (+27) 87 943 7471 www.aristonthermo.com info.za@aristonthermo.com...

This manual is also suitable for:

Andris lux 10Andris lux 15Andris lux 30

Table of Contents