Removal Of Outer Panels / Fan Motor - Daikin RKS20J2V1B Service Manual Removal Procedure

2.0/2.5/3.0/3.5 kw class
Hide thumbs Also See for RKS20J2V1B:

Advertisement

Removal of Outer Panels / Fan Motor

1. Removal of Outer Panels / Fan Motor
Procedure
Step
1. Appearance features
2. Remove the panels.
1
Remove the screw of
the stop valve cover.
Pull the stop valve
cover downward and
remove it.
2
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
(R7186)
(R16044)
Stop
valve
cover
(R7188)
Shield plate
Hook
(R13504)
Si001067
Points
Take care not to cut your
finger by the fins of the
outdoor heat exchanger.
The stop valve cover is
united with the shield plate.
When reassembling, make
sure to fit the 5 hooks.