Canon DR-5010C Startup Manual

Canon DR-5010C Startup Manual

Canon scanner startup manual
Hide thumbs Also See for DR-5010C:
Table of Contents

Advertisement

Document Scanner
Startup Manual
Please read this manual before operating this unit. After you finish
reading this manual, store it in a safe place for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for Canon DR-5010C

  • Page 1 Document Scanner Startup Manual Please read this manual before operating this unit. After you finish reading this manual, store it in a safe place for future reference.
  • Page 2 • Other product and company names here in may be the trademarks of their respective owners. Copyright Copyright 2005 by CANON ELECTRONICS INC. All rights reserved. No part of this publication may be reproduced or transmitted, in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage or retrieval system without the prior written permission of CANON ELECTRONICS INC.
  • Page 3 NO AMENDMENT TO THIS AGREEMENT SHALL BE EFFECTIVE UNLESS SIGNED BY A DULY AUTHORIZED REPRESENTATIVE OF CANON. Should you have any questions concerning this Agreement, or if you desire to contact Canon for any reason, please write to Canon's local affiliate.
  • Page 4: Introduction

    Manuals for the Scanner The DR-5010C scanner has a Startup Manual (this manual) and online help. Please refer to the Startup Manual regarding the handling of the scanner, such as installation of software and setting up the scanner. The online help explains how to use the ISIS/TWAIN driver and the enclosed software, CapturePerfect.
  • Page 5: Conventions

    Conventions This manual uses the following symbols and indications. Before you start reading this manual, read the following and familiarize yourself with their meanings. WARNING Indicates a warning concerning operations that may lead to death or injury to persons if not performed correctly. In order to use the machine safely, always pay attention to these warnings.
  • Page 6: Table Of Contents

    Power ... 6 Moving the Scanner ... 6 Normal Handling ... 7 Disposal ... 8 Features of the DR-5010C ... 9 Checking the Packing List ... 11 Removing the Protective Packing Matarials ... 12 Names and Functions of Parts ... 14 Installing the Scanner ...
  • Page 7: Before Using The Scanner

    • Provide adequate space behind the scanner in order to eject scanned documents to the back of the scanner. (See “Document Eject Tray,” on p. 45. ) • Avoid locations exposed to direct sunlight. If the scanner must be placed in such a spot, hang a heavy curtain or similar object to shade the scanner.
  • Page 8: Power

    (Either 120 V, 60 Hz or 220-240 V, 50/60 Hz depending on your region.) • Do not connect this scanner to a power outlet that is shared with other equipment. When using an extension cord, make sure that the extension cord is rated for the current requirements of the scanner.
  • Page 9: Normal Handling

    ON, immediately turn the scanner OFF and unplug the power cord. Contact your local authorized Canon dealer or service representative to have the scanner serviced.
  • Page 10: Disposal

    Canon dealer or service representative for assistance. • Do not set up the scanner in a dusty or humid location. Doing so creates a risk of fire or electrical shock. • Do not place objects on top of the scanner. The object could injure someone if it falls or tips over.
  • Page 11: Features Of The Dr-5010C

    Features of the DR-5010C The main features of the DR-5010C scanner are listed below. ■ Fast Document Feeding The scanner can scan a maximum of 50 documents per minute in a range of sizes from business cards to 11.6" x 17"/A3 size. (Scanning conditions: Black and white, LTR/A4 size portrait, two sided, 200 dpi) ■...
  • Page 12: Dropout Color

    ■ Skip Blank Page Function The scanner is equipped with a Skip Blank Page function that allows it to scan a document regardless of whether every document is double-sided or single-sided.
  • Page 13: Checking The Packing List

    USB Interface Cable Note • The DR-5010C setup disc is in the startup manual. • Items included in this package may change without notice. • Keep the carton and the packing material for future use if it is ever necessary to store or transport the scanner.
  • Page 14: Removing The Protective Packing Materials

    Removing the Protective Packing Materials Remove all of the protective packing materials (marked ▼ in the diagrams) before using the scanner. Remove the protective tape from the scanner. Slowly open the Document Feed Tray, then remove the protective tape. Feed tray Hold the edge of the Upper unit as shown in the diagram, and slowly open it until it stops.
  • Page 15 Replace the roller cover. Roller Cover Retard Roller Gently close the Upper unit. Be sure that the Upper unit is completely closed by pushing on both edges with both hands until you hear a click. Pickup Roller Before Using the Scanner...
  • Page 16: Names And Functions Of Parts

    Names and Functions of Parts This section explains the name and function of each part. Familiarize yourself with the parts before connecting the scanner. ■ Front (Feed Tray Open) Document Feed Tray Place the document to be scanned here. (See p. 44.)
  • Page 17 Interface Ventilation Openings CAUTION Do not block the Ventilation Openings. Doing so could cause the scanner to overheat, creating a risk of fire. ■ Interface Not Used USB Connector Connect the USB cable provided or one that supports Hi-Speed USB 2.0. (See p. 23.) CAUTION Do not connect anything to the connectors that are not used.
  • Page 18: Installing The Scanner

    Installing the Scanner Installation Requirements In order to use the DR-5010C, your computer must satisfy the following system requirements: • A computer that meets the following specifications: - CPU: Pentium 4 (1.5 GHz or higher) - Memory: 512 MB or more (1 GB or more recommended)
  • Page 19 • The ISIS/TWAIN driver provided with the scanner is not necessarily compatible with all ISIS compatible or TWAIN compatible application software. For details, contact your local authorized Canon dealer or service representative. Installing the Scanner...
  • Page 20: Installation Procedure

    Installation Procedure The procedure for installing the scanner is outlined below. (For a detailed outline of this procedure, see “Connecting the Scanner to Your PC,” on p. 21.) 1. Check the interface card in your computer. (See “Interface Cards,” on p. 19.) 2.
  • Page 21: Interface Cards

    Interface Cards To connect the scanner with a SCSI connection, make sure that the SCSI card is one of the recommended cards listed below that supports SCSI III. SCSI Cards When connecting the scanner via SCSI, verify that the SCSI card you are using is one recommended for use with the scanner.
  • Page 22 USB 2.0 interface card into your computer. • Use the most recent version of the USB 2.0 driver provided by Microsoft. Note If the USB 2.0 interface is not compatible with Hi-Speed USB 2.0, scanning speed is reduced. Installing the Scanner...
  • Page 23: Connecting The Scanner To Your Pc

    Connecting via SCSI Notes on the Shape of Connectors and the SCSI Cable • The DR-5010C is equipped with a 50-pin half-pitch (pin type) SCSI Connector. • The SCSI cable is not provided with the scanner. Check the shape of SCSI connectors on your computer and the scanner, and use a SCSI cable that has compatible connectors.
  • Page 24 • The SCSI ID is set to 2 at the factory. • The SCSI ID is set with the Dip Switches on the back of the scanner. The Dip Switches are on when they are down, and off when they are up.
  • Page 25: Connecting Usb Interface

    IMPORTANT • If the operating system you are using is Windows NT, the connection via USB is not supported. When using the DR-5010C with Windows NT, be sure to connect the scanner via SCSI. • When using a USB hub, be sure to use one compatible with USB 2.0.
  • Page 26: Connecting The Power Cord

    Connecting the Power Cord Connect the power cord that is provided with this scanner to the power cord connector located on the rear of the scanner, and then plug the cord into a power outlet. WARNING • Be sure to use the power cord provided with the scanner.
  • Page 27: Turning The Power On/Off

    Turning the Power ON Turn ON the scanner. The Power Switch is on the lower left of the front of the scanner. Push the Power Switch to turn ON the scanner. The power lamp lights green when the power is ON.
  • Page 28 1. Insert the setup disc into the computer’s CD-ROM drive. 2. On the Welcome to the Found New Hardware Wizard screen, select [Install from a list or specific location (Advanced)], and then click the [Next] button. Installing the Scanner...
  • Page 29: Turning The Power Off

    OFF, the scanner is OFF. Note • When connecting the DR-5010C via SCSI, turn the scanner ON first, and then turn the PC ON. • Wait at least 10 seconds before turning the scanner ON aftter it has been turned OFF.
  • Page 30: Installing The Software

    Before installing the software, be sure to open and read the Readme.txt file on the setup disc. The setup disc included with the scanner contains the following software: • ISIS/TWAIN Driver This driver allows this scanner to be used with ISIScompatible application software or TWAINcompatible application software.
  • Page 31 Click the [Start] button, and then select [Run]. The [Run] dialog box appears. In the Open box, enter “D:\Driver\Setup.exe” (assuming that “D” is the letter assigned to your CD-ROM drive), and then click the [OK] button. The Installer starts. Follow the instructions on the screen and complete the installation. Restart Windows when you have completed the installation.
  • Page 32 (See “Using Patch Code Sheets,” on p. 55.) To use the patch code sheets, you need to install CapturePerfect, which is provided with the scanner, or an application that can handle PDF format files. Installing the Software...
  • Page 33: Installing Captureperfect

    Installing CapturePerfect Follow the procedure described below to install CapturePerfect. Turn ON your PC. Windows starts. IMPORTANT If you are using Windows NT 4.0 Workstation, Windows 2000 Professional, or Windows XP, be sure to log on as a user with administrator privileges. Insert the setup disc in the PC’s CD-ROM drive.
  • Page 34: Uninstalling Software

    Uninstalling Software Follow the procedure described below to uninstall the ISIS/TWAIN driver and CapturePerfect. IMPORTANT If you are using Windows NT 4.0 Workstation, Windows 2000 Professional, or Windows XP, be sure to log on as a user with administrator privileges. Click the [Start] button, point to [Settings], and then click [Control Panel].
  • Page 35 Note If you are using Windows XP, the [Add or Remove Programs] dialog box is displayed. Select [Canon DR-5010C Driver] or [CapturePerfect] from the list in the dialog box, and then click [Add/Remove]. Note If you are using Windows XP, click the [Change/Remove] button.
  • Page 36 The [Confirm File Deletion] dialog box appears. When [Canon DR-5010C Driver] is selected. When [CapturePerfect] is selected Click the [Yes] button to start the uninstaller. Follow the instructions on the screen to finish uninstalling the software. Installing the Software...
  • Page 37: Using The Software

    To access ISIS/TWAIN driver help, click the [Start] button, point to [Programs] (when using Windows XP, point to [All Programs]) - [Canon DR- 5010C], and then click [Canon DR-5010C Help], or click the Help button displayed in the dialog box.
  • Page 38: Using Captureperfect

    CapturePerfect help. From the [Help] menu on the CapturePerfect menu bar, click [Help], then refer to the explanation of how to use CapturePerfect. Starting CapturePerfect Turn ON the scanner. Turn ON your computer. Windows starts. Click the [Start] button, point to [Programs] (when using Windows XP, point to All Programs), and then click [CapturePerfect].
  • Page 39 On the Scan menu, click [Select Scanner]. Select [Canon DR-5010C], and then click the [OK] button. Note If [Canon DR-5010C] is not displayed in the list of scanners, re-install the ISIS/TWAIN driver. (See “Installing the ISIS/TWAIN Driver” on p. 28. ) Using the Software...
  • Page 40 On the Scan menu, click [Scanner Setting] and then configure scanning parameters. Note For details about how to configure scanning parameters, see ISIS/TWAIN driver help. (See p. 35.) Execute the scan operation from the [Scan] menu. Note Details about actually using CapturePerfect can be found in CapturePerfect help.
  • Page 41: Starting Captureperfect With The Event Function

    Starting CapturePerfect with the Event Function DR-5010C and CapturePerfect support Windows Scanner Event function. By installing the ISIS/TWAIN driver and CapturePerfect, CapturePerfect starts automatically when the scanners Start Button is pressed. Note Windows NT does not support this function. Confirming Scanner Event Double-click the [Scanners and Cameras] icon.
  • Page 42 Select [Canon DR-5010C SCSI] (or [Canon DR-5010C USB]), and then click the [Properties] buton to display Properties. Click the [Events] tab. Using the Software...
  • Page 43 Make sure that [CapturePerfect] is checked. Note • When an application is started by an event, it may not work correctly depending on the application. • To disable the Event function, check the [Disable device events] check box. • Restart Windows to enable new settings after changing the event settings. Using the Software...
  • Page 44: Using The Scanner

    • Scanning documents before the ink is dry can cause problems with the scanner. Always make sure that the ink on a document is dry before scanning it. Using the Scanner Straight Path 2.08"...
  • Page 45 Straight Path. CAUTION The results of scanning embossed cards are not guaranteed. Note that scanning embossed cards may scratch the sensor glass. Embossed Cards Documents Extremely with paper thin, clips or translucent staples paper Carbon paper Coated paper Using the Scanner...
  • Page 46: Setting Up The Document Feed Tray And The Document Eject Tray

    CAUTION Do not place anything other than documents on the Document Feed Tray. Doing so may damage the scanner, reduce scanning quality, or cause the feed tray to fall off and injure someone. Pull out the Document Feed Tray Extension when scanning large documents.
  • Page 47: Document Eject Tray

    The scanner has two eject methods; documents can be eject to the front of the scanner in a U-Turn Path, or to the back of the scanner in a Straight Path. The eject method can be switched by opening or closing Document Eject Tray 2.
  • Page 48 IMPORTANT • Be sure there is enough space for documents that are ejected behind the scanner when using the Straight Path. If there is not enough space for ejected documents, the documents may be damaged or a paper jam may occur.
  • Page 49: Installing The Document Eject Guide

    When scanning a document that is particularly thin or particularly long, it could droop down over the edge of the Document Eject Tray Extension and become jammed in the scanner. Avoid this problem by attaching the Document Eject Guide. Open the Document Eject Tray Extention toward you.
  • Page 50 To remove the Document Eject Guide, lift the Document Eject Tray Extension a little and unhook the Document Eject Guide. Reverse the procedure for attaching the Document Eject Guide to remove it. Using the Scanner...
  • Page 51: Placing A Document For Scanning

    • Do not wear loose clothing or jewelry that may get caught in the scanner while you are operating it. If they get caught in the scanner it may cause an injury. Be extra careful of neckties and long hair. If anything gets caught in the scanner, quickly unplug the scanner to stop it.
  • Page 52 Straighten the edges of the document to be scanned. CAUTION • Do not place the documents on top of the scanner to align them. Doing so may cause a malfunction. • Be careful when placing a document in the scanner. It is possible to cut your hand on the edge of a sheet of paper.
  • Page 53 Adjust the document guides so they matche the width of the document. Note Before starting a scan, make sure that the document is loaded in the scanner correctly. Scanning a curled document or a creased document can damage the document.
  • Page 54: How To Feed With The Bypass Mode

    How to Feed with the Bypass Mode Move the Feed Selection Lever on the lower left side of the front of the scanner down ( Note • Lowering the Feed Selection Lever causes the Document Stoppers to go down. • The ISIS/TWAIN Driver settings change to the manual feed mode automatically when the Feed Selection Lever is lowered.
  • Page 55 When doing this, be careful not to get your fingers stuck in the pickup roller. • After you finish scanning, close the Document Feed Tray and the Document Eject Tray Extension to prevent damage to the scanner while it is not being used. Pickup Roller...
  • Page 56: Patch Code Sheets

    There are 4 types of Patch Code Sheets: [PATCH II (A4)], [PATCH II (LTR)], [PATCH T (A4)], and [PATCH T (LTR)]. Click the [Start] button in Windows, point to [Programs] – [Canon DR-5010C], and then click [PATCH X(XX)]. Then print the sheets to use them.
  • Page 57: Functions Of Patch Code Sheets

    When this sheet is detected, the file is separated after this sheet. Note, however, that the setting is ignored, and this sheet is recorded as an image even if the recording of the sheets as an image has been disabled in the patch code detection settings. Using the Scanner...
  • Page 58: Effective Area For Detecting Patch Code Patterns

    Damaged or marked patch code sheets cannot be read correctly. • To avoid a reading error, make sure that the scanning density for patch code sheets is neither too light nor too dark. Using the Scanner 0.2" (5 mm) 0.2" (5 mm) 3.7"...
  • Page 59: Clearing A Paper Jam

    The pickup roller is located in the middle of the Upper unit. Do not hold the protrusion on the Upper unit when you open it. Doing so may deform the pickup roller or cause a feeding error. Using the Scanner...
  • Page 60 Close the Upper unit slowly. Be sure that the Upper unit is completely closed by pushing on both edges with both hands until you hear a click. Using the Scanner...
  • Page 61 IMPORTANT Do not force the Upper unit to close. Doing so may damage the scanner. Note After removing the jammed paper, check to see if the last page was scanned, and then continue scanning. Using the Scanner...
  • Page 62: Other Functions

    If long documents are skewed, then they may rub against the feed slot or the edges of the feed path and be damaged. The scanner is equipped with a Skew Detector function that detects when a skewed document hits the edge of the feed slot.
  • Page 63: Regular Maintenance

    ON. Cleaning the Scanner To clean the exterior of the scanner, dampen a cloth with water or a mild detergent, wring the cloth out thoroughly, and then wipe the dirt away. Then use a dry, soft cloth to wipe away any moisture.
  • Page 64: Cleaning The Sensor Glass And The Rollers

    Cleaning the Sensor Glass and the Rollers If scanned images have extraneous marks, or if the scanned documents are dirty, then the sensor glass or rollers inside the scanner may be dirty. Clean them periodically. Hold the Upper unit as shown in the diagram, and open it slowly until it stops.
  • Page 65 Scratches on the sensor glass may cause marks on the images and could cause feeding errors. If there are scratches on the sensor glass, contact your local authorized Canon dealer or service representative to replace the sensor glass. Wipe the rollers with a firmly wrung cloth moistened with water.
  • Page 66 Close the Upper unit slowly. Be sure that the Upper unit is completely closed by pushing on both edges with both hands until you hear a click. IMPORTANT Do not force the Upper unit to close. Doing so may damage the scanner. Regular Maintenance...
  • Page 67: Cleaning The Shading Boards

    Cleaning the Shading Boards The shading boards are the white standard boards located behind the platen rollers. A dirty shading board may alter scanned colors or cause marks on the images. Turn ON the power. Hold the Upper unit as shown in the diagram, and open it slowly until it stops. CAUTION The pickup roller is located in the middle of the Upper unit.
  • Page 68 Close the Upper unit slowly. Be sure that the Upper unit is completely closed by pushing on both edges with both hands until you hear a click. IMPORTANT Do not force the Upper unit to close. Doing so may damage the scanner. Regular Maintenance...
  • Page 69: Removing And Attaching The Rollers

    CAUTION • Turn ON the power to the scanner to remove or attach the pickup roller. Be careful when working on the scanner when the power is ON.
  • Page 70: Resetting The Counter

    • Contact your local authorized Canon dealer or service representative for information about the exchange roller kit (pickup roller, retard roller, and feed roller). Resetting the Counter After replacing the feed rollers, reset the counter according to the following procedure.
  • Page 71 Click on [Properties] for the scanner you are using. Click the [Counter] tab. Press the [Reset] button, and then make sure that the counter for the Roller being used is set to 0. Regular Maintenance...
  • Page 72: Removing And Attaching The Pickup Roller

    Follow the procedures below to remove and attach the pickup roller for cleaning or replacement. CAUTION • Turn ON the power to the scanner to remove or attach the pickup roller. Be careful when working on the scanner when the power is ON.
  • Page 73 Hold the new pickup roller (or the one you removed) by both sides of its shaft, and place it on the hooks. IMPORTANT Take note of the orientation of the pickup roller. Putting it in backward and forcing it may damage the scanner. Regular Maintenance...
  • Page 74 Close the Upper unit slowly. Be sure that the Upper unit is completely closed by pushing on both edges with both hands until you hear a click. IMPORTANT Do not force the Upper unit to close. Doing so may damage the scanner. Regular Maintenance...
  • Page 75: Removing And Attaching The Feed Roller

    Removing and Attaching the Feed Roller Follow the procedure below to remove and attach the feed roller unit for cleaning or replacement. CAUTION Do not use excessive force when removing or attaching the rollers. Doing so may damage them. Removing the Feed Roller Hold the Upper unit as shown in the diagram, and open it slowly until it stops.
  • Page 76 Move the roller lock lever down and forward (➀), and then slide it to the right (➁). Shift the feed roller to the right to remove it. Attaching the Feed Roller Position the feed roller so the notch in the roller is facing the scanner's shaft. Regular Maintenance...
  • Page 77 Slide the roller lock lever to the left, and insert it into the feed roller hole. Lift up the roller lock lever and lock the feed roller. Attach the roller cover. Regular Maintenance...
  • Page 78 Close the Upper unit slowly. Be sure that the Upper unit is completely closed by pushing on both edges with both hands until you hear a click. IMPORTANT Do not force the Upper unit to close. Doing so may damage the scanner. Regular Maintenance...
  • Page 79: Removing And Attaching The Retard Roller

    Removing and Attaching the Retard Roller Follow the procedure below to remove and attach the retard roller when you clean or replace it. CAUTION Do not use excessive force when removing or attaching the rollers. Doing so may damage them. Removing the Retard Roller Hold the Upper unit as shown in the diagram, and open it slowly until it stops.
  • Page 80 Move the roller lock lever upward (➀), and then slide it to the right (➁). Shift the retard roller to the right to remove it. Attaching the Retard Roller Position the retard roller so the notch in the roller is facing the scanner's shaft. Regular Maintenance...
  • Page 81 Slide the roller lock lever to the left, and insert it into the retard roller hole. Move the roller lock lever forward and down to lock the retard roller. Attach the roller cover. Regular Maintenance...
  • Page 82 Close the Upper unit slowly. Be sure that the Upper unit is completely closed by pushing on both edges with both hands until you hear a click. IMPORTANT Do not force the Upper unit to close. Doing so may damage the scanner. Regular Maintenance...
  • Page 83: Troubleshooting

    Resulting Scanned Images Are Not Correct ... p. 86 If after consulting the above section you still cannot resolve the problem, contact your local authorized Canon dealer or your service representative. The Scanner Does Not Turn ON Check the following: •...
  • Page 84: The Pc Does Not Recognize The Scanner

    The PC Does Not Recognize the Scanner (Connecting via SCSI) The following are possible causes of the PC failing to recognize the scanner. Check each possible cause. Cause The scanner is not connected correctly. Remedy Make sure that the scanner and the computer are correctly connected.
  • Page 85 Refer to “The Scanner Does Not Turn ON,” on p. 81 and check to see if the scanner is ON. If the scanner is not ON, shut down the PC, then turn the scanner ON first, and then the PC.
  • Page 86: The Pc Does Not Recognize The Scanner

    The PC Does Not Recognize the Scanner (Connecting via USB 2.0) The following are possible causes of the PC failing to recognize the scanner. Check each possible cause. Cause The scanner is not connected correctly. Remedy Check the USB cable connections between the scanner and the PC.
  • Page 87: Scanning Is Slow (Connecting Via Usb 2.0)

    Remove the USB HUB or replace it with one that supports HI-Speed 2.0. (See p. 23.) Images Are Not Scanned Check the following if the scanner does not scan an image even though the scanning operation is being performed: • Is the scanner correctly connected to the PC? •...
  • Page 88: Resulting Scanned Images Are Not Correct

    Driver,” on p. 28. For details on how to install the application software, refer to the application software instruction manual. Cause Attempting to use a function of the DR-5010C that is not supported by the application software. Remedy Some application software may not support certain functions, such as automatically detecting the paper size or changing the scanning mode/resolution through the scan panel.
  • Page 89: Specifications

    (Primary Scan Lines x Secondary Scan Lines) 240 x 240 dpi, 300 x 300 dpi, 400 x 400 dpi Scanning Speed Black and White 256-level Gray Sheet through image scanner 2.08" to 11.8" (53 to 300 mm) 2.75" to 17" (70 to 432 mm) 14 to 32 lb bond (0.0024"...
  • Page 90: Replacement Parts

    Kit to replace the feed rollers (pickup roller, feed roller, and retard roller). • Refer to “Removing and Attaching the Rollers,” on p. 67 for information about replacing the rollers. • Contact your local authorized Canon dealer or service representative for detailed information about the options and replacement parts. Specifications...
  • Page 91 External Dimensions Units: inches (units in parentheses are millimeters) 26.3" (668) (Document Feed Tray Extension is open) (Document Feed Tray is open) 21.3" (541) 17.3" (440) (Document Eject Guide is open) 12.3" (312) Specifications 3.7" (95) (Document Eject Tray 2 is open)
  • Page 92: Index

    Install ... 31 Uninstall ... 32 Using ... 36 Cleaning Glass ... 62 Inside ... 61 Rollers ... 62 Scanner ... 61 Shading Board ... 65 Connections Power Cord ... 24 SCSI ... 15,21 USB 2.0 ... 15,23 DIP Switches ... 15 Disposal ...
  • Page 93 MEMO...
  • Page 94 MEMO...
  • Page 95 Do not make any changes or modifications to the equipment unless otherwise specified in the manual. If such changes or modifications should be made, you could be required to stop operation of the equipment. Canon U.S.A. Inc. One Canon Plaza, Lake Success NY 11042, U.S.A. Tel. No. (516)328-5600 RADIO INTERFERENCE REGULATIONS (For 120 V models) This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the Interference-causing equipment standard entitled "Digital Apparatus", ICES-003 of the Indus-...
  • Page 96 CANON ELECTRONICS INC. 1248, SHIMOKAGEMORI, CHICHIBU-SHI, SAITAMA 369-1892, JAPAN CANON U.S.A. INC. ONE CANON PLAZA, LAKE SUCCESS, N.Y. 11042, U.S.A. CANON CANADA INC. 6390 DIXIE ROAD, MISSISSAUGA, ONTARIO L5T 1P7, CANADA CANON EUROPA N.V. BOVENKERKERWEG 59-61, P.O.BOX 2262, 1180 EG AMSTELVEEN, THE NETHERLANDS CANON LATIN AMERICA, INC.

This manual is also suitable for:

9842a002

Table of Contents