Quick Links

Tools Required:
Step 1: Wire cutters, Phillips screw driver, 9/64" hex
driver, 6 nylon zip ties and a grounding wrist strap.
Step 3: Turn off, unplug the power cord and the com-
munication cable. Remove the right cover.
Step 5: Remove the rear cover (18) screws. Place to
the side.
Step 7: Unclip the Y belt from the carriage. Remove
the carriage from the traverse by pressing down on
the threaded screw (arrow), then pull forward.
Install Ribbon Cable 3C FJE
Kit for # 109519, Procedure P/N 110623 Rev 0
1
Step 2: The ribbon cable. Should come with the 6
nylon cable zip ties to attach to the carriage.
Step 4: After removing the left cover, using the hex
driver, loosen the belt by turning the screw (arrow) 2
turns counter clockwise.
Step 6: Remove the carriage cover (4) screws.
Step 8: You need to start to remove the old ribbon
cable. With the wire cutters, snip all the white cable
ties. There should 5. Cut and remove them.
14140 NE 200th St.
Woodinville, WA 98072
1.425.398.8282
www.ioline.com

Advertisement

loading

Summary of Contents for Ioline FlexJet E

  • Page 1 14140 NE 200th St. Woodinville, WA 98072 Kit for # 109519, Procedure P/N 110623 Rev 0 1.425.398.8282 www.ioline.com Tools Required: Step 1: Wire cutters, Phillips screw driver, 9/64” hex Step 2: The ribbon cable. Should come with the 6 driver, 6 nylon zip ties and a grounding wrist strap.
  • Page 2 14140 NE 200th St. Woodinville, WA 98072 1.425.398.8282 www.ioline.com Step 9: All the zip ties have been removed. Step 10: Turn the carriage over. You need to pull the connectors off the carriage board pins. NOTE: Be careful not to bend those small pins.
  • Page 3 14140 NE 200th St. Woodinville, WA 98072 1.425.398.8282 www.ioline.com Step 18: Turn the carriage over. Step 17: With the new cable, start by laying the cable over the top of the carriage as shown. NOTE: No cable ties at this point.
  • Page 4 14140 NE 200th St. Woodinville, WA 98072 1.425.398.8282 www.ioline.com Step 26: Re-attach the Y belt to the carriage and Step 25: Place the carriage back onto the traverse with tighten the Y belt using the tensioner (2 turns clock- the cable placed into the channel as shown.

This manual is also suitable for:

Flexjet e-ii