Commissioning the system
Pump/component
Heating circuit pump and mixer M3
(controlled via mixer extension kit)
Circulation pump for cylinder heating
DHW heating
with cylinder loading system:
Cylinder loading pump
2-way shut-off valve
DHW circulation pump
Solar thermal system
Circulation pump for DHW reheating
Remote control (e.g. Vitotrol 200-A)
Vitocom 100
External H1 extension
Commissioning, inspection, maintenance
(cont.)
Parameter
"System definition"
Ó
"System scheme 7000"
"System definition"
Ó
"System scheme 7000"
"Internal hydraulics"
"Enable 3-
Ó
way diverter valve heating/DHW
730D"
"System definition"
Ó
"System scheme 7000"
"External heat source"
Ó
"Enable external heat source for
DHW heating 7B0D"
Extended menu:
"Time prog. DHW circ."
"Solar"
Ó
"Type solar control unit 7A00"
"External heat source"
Ó
"Enable external heat source 7B00"
"External heat source"
Ó
"Enable external heat source for
DHW heating 7B0D"
"Heating circuit 1"
Ó
"Remote control 2003"
or
"Heating circuit 2"
Ó
"Remote control 3003"
or
"Heating circuit 3"
Ó
"Remote control 4003"
"System definition"
Ó
"Vitocom 100 7017"
"System definition"
Ó
"External extension 7010"
Setting
With heating circuit with mixer
M3
Note
Set rotary switch S1 in the ex-
tension kit to "2" (see "Mixer
extension kit" installation in-
structions).
With DHW heating
"0"
With DHW heating
"1"
Setting a time program
"1" (with Vitosolic 100)
"2" (with Vitosolic 200)
"1"
"1"
"1"
Note
Set code on the Vitotrol 200-
A to assign heating circuits:
H1 for heating circuit A1
H2 For heating circuit M2
H3 For heating circuit M3
(see "Vitotrol 200-A" installa-
tion instructions)
"1"
"1"
Note
For parameters for external
functions, see the following
table.
81