Viessmann VITOCAL 350-A Installation And Service Instructions Manual page 14

Air/water heat pump with electric drive, 400 v~
Hide thumbs Also See for VITOCAL 350-A:
Table of Contents

Advertisement

Installation preparations for heat pumps installed indoors
Requirements for transport and siting: Type AWHI 351.A
Wall clearances
g
830
A B
E
D
H
M
K
240
e
Fig. 5
Exterior rendering
A
Wall
B
Wall duct (EPP, can be trimmed to the correct size
D
from the outside with a saw. Observe plaster thick-
ness!)
Compression sealing tape and acrylic airtight
E
seam (all-round)
PU foam (all-round)
F
Appliance connector, air duct on the intake side
G
(EPP)
Plaster finish/wall coating
H
Dim.
Vitocal 350-A, type AWHI
351.A10
e
mm
489
g
mm
880
Distances between wall openings X and Y in mm
N
Vitocal 350-A, type AWHI
351.A10
X
1
655
2
1005
3
1355
4
1705
5
2055
6
2405
7
2755
8
3105
9
3455
10
3805
14
F G
Q
N
N x 350
351.A14
351.A20
489
1020
1180
351.A14
Y
X
680
660
1030
1010
1380
1360
1730
1710
2080
2060
2430
2410
2780
2760
3130
3110
3480
3460
3830
3810
(cont.)
X
Y
F
E
D
Hydraulic and condensate connections
K
Heat pump
M
Appliance connector, air duct on the discharge
N
side (EPP)
Air duct 90° bend
P
Partition wall (if required): See table on pages 14
Q
and 15.
N
Number of duct parts (wall ducts)
X
Distance between wall openings inside the building
Y
Distance between wall openings outside the build-
ing
472
351.A20
Y
X
755
665
1105
1015
1455
1365
1805
1715
2155
2065
2505
2415
2855
2765
3205
3115
3555
3465
3905
3815
830
810
D
P
885
Partition wall
required
Y
840
1190
1540
1890
2240
2590
2940
3290
3640
3990
Q
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No