Adjustment
52
600
602
Inputs: 0123456789ABCDEF
(2571, 2574, 2591 PREMIUM only),
0 = Needle mid point (E16)
1 = Needle mid point (E15)
2 = Intermittent coding (E14)
3 = Free (E13)
4 = Free (E12)
5 = Free (E11)
6 = Free (E10)
7 = Free (E9)
8 = Emergency button (E8)
9 = Free (E7)
A = Knee switch (E6)
B = Photo cell (E5)
C = Starting inhibitor (E4)
D = Single stitch button on
E = Half stitch button on
F = Reverse button on
603
Machine drive in home position see
set-up-instructions
604
Run cold start
605
Stitch process with step motors by handwheel
606
Display speed control unit value
7
701
P-section speed regulator
2571, 2591
2574
702
I-section speed regulator
703
P-section position regulator
704
D-section position regulator
705
Time for position regulator
706
P-section position regulator for remainder brake
707
D-section position regulator for remainder brake
708
Maximum torque for remainder brake
709
Minimum machine speed
machine head (E3)
machine head (E2)
machine head (E1)
0 - 127
8 ± 2
1 - 50
30
1 - 50
20
0 - 100
50
1 - 50
20
1 - 100
30
0 - 100
25
1 - 50
25
1 - 50
15
0 - 100
0
3 - 64
6