Adjustment
3
Reset / Cold start
.02
After selecting the reset menu, by pressing the corresponding key it is possible to delete
seam parameters, delete seam programs and to carry out a cold start.
Resetting the seam parameters
Resetting the seam programs
Cold start
20
A
Press and hold "+" on keys A and D and switch on the machine.
RESET
A
B
Press "+" on key A.
All seam parameters are deleted, "MASTER-RESET" is displayed for a short time on the
screen.
Press "+" on key B.
All seam programs are deleted, "MASTER-RESET" is displayed for a short time on the
screen.
Press "+" on key D.
The values of the machine control unit are set back to their basic values, except the value
for the machine class. "COLD START" is displayed for a short time on the screen.
After the cold start all programmed values are set back to their status at the
time of delivery. For this reason after a cold start it is necessary to re-enter first
the parameter 799, 800 and then the parameter 700.
The parameter which differ from the basic values are listed in the machine
instruction manual.
D
Y - N