Test Block 1 - Inputs; Test Block 2 - Outputs; Test Block 3 - Speed Control Unit; Test Block 4 - Actual Value Transmitters - Pfaff EcoDrive P40 ED Instruction Manual

Hide thumbs Also See for EcoDrive P40 ED:
Table of Contents

Advertisement

Adjustment
3.
Test block 2 – outputs
01.03
Output number
3.
Test block 3 – speed control unit
01.04
control unit
3.
Test block 4 – actual value transmitters
01.05
Actual value
transmitter
18
A 1
X5:
28
Output
Connector
Contact
number
The functions allocated to the inputs displayed can be found in Part 3 Parameter list and
connection plan.
SWG
-2
D
Speed
Pedal
position
It is possible to move to all 16 switch levels by operating the pedal.
If all the displays from -2, -1, 0, 1, 1D to 12D appear, the speed control unit is in order.
IWG
136
Increments
The actual value transmitter can be checked by turning the balance wheel.
If the increments from 0 – 255 appear on the display, the actual value transmitter is in order.
0
D
Output status
The output can be switched on
for 200 ms by pressing key D+

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecodrive p70 ed

Table of Contents