Wall Pre-Installation; Minimum Clearances - Vaillant atmoMAG MAG mini 114/1 I Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Num-
Designation
ber
Battery (monocells D/LR20)
1
Note
The battery is inserted in the lower Styrofoam cushion.
4.2

Wall pre-installation

3
60
2
Flush mounting
3
60
2
Surface installation
Install the connections as follows:
1 = Cold water connection R 1/2
2 = Gas connection
3 = R 1/2 hot water connection
Observe the following clearances for all product types:
a = 92 mm
b = 85 mm
c ≈ 100 mm without thermal isolator device
c ≈ 145 mm with thermal isolator device
4.3

Minimum clearances

C
C
0020273765_00 atmoMAG Installation and maintenance instructions
1
60
1
60
D
A
50 mm
B
180 mm; optimum approx. 250 mm
C
20 mm; optimum approx. 50 mm
D
500 mm in front of the heat generator to enable
easy access for maintenance work (may be
provided by an opening door).
It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances.
Set-up 4
Minimum clearance
7