Removal Of Electrical Component Assy (Pattern 1) - Daikin R13LV2S Service Manual

Advertisement

Removal of Electrical Component ASSY (Pattern 1)

3. Removal of Electrical Component ASSY
(Pattern 1)
Procedure
Step
1
Pull out the terminal
(blue) from K1M (1).
2
Pull out the 2 terminals
(red, yellow) from the
compressor capacitor
(C1R).
Remove the electrical
3
component ASSY.
18
Warning
Be sure to for wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
2
4
6
14
A2
K1M
C1R
to compressor
(R terminal): red
K1M
C1R
K1M
C1R
C2R
to compressor
(C terminal): blue
1
3
5
13
A1
(R16341)
to compressor
(S terminal): yellow
(R17458)
C2R
F1U
V1R
F1U
V1R
(R16342)
Si011184
Points
Compressor lead wire
S (W)
C (U)
R (V)
(R15393)
S (W): yellow
C (U): blue
R (V): red
Removal Procedure