Removal of Outer Panels / Fan Motor (Pattern 1)
Step
4. Remove the right side
panel.
Remove the 7 screws
1
on the terminal board
and disconnect the
connecting wire and the
power supply wire.
Remove the screw and
2
remove the wire clamp.
Lift up and remove the
3
guard net.
Remove the 2 screws
4
on the rear side.
8
Procedure
Terminal board
Wire clamp
Connecting
wire
Guard net
Power supply
wire
(R16537)
(R8284)
(R15237)
Si011184
Points
Removal Procedure