Duct Collars; Control Location - Aprilaire E080CS Installation And Operation Manual

Hide thumbs Also See for E080CS:
Table of Contents

Advertisement

DUCT COLLARS

Use the screws in the parts bag to attach the duct collars to the
inlet and outlet of the dehumidifier . The outlet collar has a backflow
damper . See Figure 3 .

CONTROL LOCATION

The on-board control can be located on the top of
the dehumidifier or can be relocated to the front
of the dehumidifier if the control cannot be seen/
accessed in the top orientation . It may also be
rotated 180 degrees in either orientation as shown
in Figure 5 .
To move the control:
1. Remove the top control panel cover .
2. Remove the filter access door and filter .
3. Detach the on-board control by removing the four
(4) screws around the control . NOTE: Use one
hand to support the back of the on-board control
when removing .
4. Keep the control in the unit and relocate to the
top access hole .
5. Secure the control with the same four screws
used to attach the control to the front of the unit .
6. Secure the control panel cover to the front of the
unit .
4
FIGURE 3 – Install Duct Collars
INLET
DUCT
COLLAR
FIGURE 4 – Control Location
CONTROL
CONTROL
PANEL COVER
FIGURE 5 – Control Rotated 180 Degrees
OUTLET COVER
OUTLET DUCT
COLLAR W/BACK
DRAFT DAMPER
END DISCHARGE
CONTROL
PANEL COVER
CONTROL
FILTER ACCESS DOOR
90-1909
90-1884
90-2525