C. ERROR INDICATION
C. ERROR INDICATION
C. ERROR INDICATION
C. ERROR INDICATION
C. ERROR INDICATION
The Display will show an error indication for self diagnosis as follows.
"E" means that a service technician is required.
"U" means that user can correct the operation.
Display
Trouble
●Microwave relay is welded.
E-12
●Magnetron thermistor in mode heater
a temperature of 90℃ or higher.
●Thermistor (on cavity) senses a
temperature of 300℃ or higher.
E-21
●Heater relay (upper) is welded.
●Thermistor on cavity temperature of
240℃ or higher.
●Thermistor (on Magnetron or Oven)
E-31
is shorted.
●Thermistor (on Magnetron, Oven or
E-32
upper Heater) senses a temperature
of 20℃ or lower.
●One touch memory cooking is not
E-22
available.
●When the Memory key is pressed
after 30 sec. or more have passed
from closing the door.
U-50
●When the START key is pressed
30 sec. or more have passed
after heater preheating finished.
Thermistor connector
Other Symptom
●Oven stops heating.
●Buzzer continuously beeps.
●Oven stops heating.
●Buzzer continuously beeps.
●Blower motor will stop
immediately.
●Oven stops heating.
●Oven stops heating.
●Buzzer does not beep.
―
●Memory key and Start key are
not available.
Duct
8000
7000
6000
5000
Magnetron
4000
3000
2000
1000
0
‑ 14 ‑
Solution
●Check for relay circuit board on Blower motor.
→ This error function will be cancelled when the
CLEAR key is touched.
●Check and remove the cause of the cavity fire
or abnormal overheating. (such as operation
with no food)
●Check for relay circuit board.
→ This error function will be cancelled when the
power cord is unplugged.
●Check for short-circuit of thermistor itself or
wire insulation of thermistor.
→ This error function will be cancelled when the
power cord is unplugged.
●Check for open-circuit of thermistor itself or
improper connection of wire socket of
thermistor.
●Check for upper heater.
→ This error function will be cancelled when the
CLEAR key is touched.
Check for error count on PCB board.
→ See page 8.
→ This error function will be cancelled when
the door is opened and closed, or the power
cord is unplugged.
Thermistor Chart
0
10
20
30
Temperature (°C)
40
50
60