RAID level
RAID 0
RAID 1
RAID 5
In order to permanently remove an operational HDD/SSD module that is part of
a RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
Be sure to back up your data before deleting a RAID array.
For more information, see the "ServerView Suite RAID
Management" user guide.
Removing a 2.5-inch HDD/SSD module
▶ Pinch the green locking clips and open the locking lever (see
▶ Pull the HDD/SSD module out a few centimeters.
▶ Wait about 30 seconds.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
This period is necessary for the RAID controller to recognize that an
SSD module has been removed.
RX2530 M6
Hard disk drive (HDD) / solid state disk (SSD)
Procedure
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all
data are lost!
Removing an HDD/SSD module from a RAID 1 or
RAID 5 array will not result in data loss. However,
the removed drive needs to be replaced
immediately by an HDD/SSD module of the same
or larger capacity.
After replacing the HDD/SSD module,
RAID rebuild will be performed as a
background process, see
RAID array rebuild" on page
Upgrade and Maintenance Manual
"Performing a
94.