Signal Converter Sono 3000 - Siemens SITRANS F US SONOFLO SONO 3300 Handbook

Ultrasonic flowmeter sensor type and signal converter type
Hide thumbs Also See for SITRANS F US SONOFLO SONO 3300:
Table of Contents

Advertisement

® ® ® ® ®
SITRANS F US SONOFLO
2.2 Signal converter
SONO 3000
Enclosure IP 67
Enclosure IP 20,
front of panel
6
2. Technical data
Analog output
Measurement of: (optional via menu)
Current
Load
Time constant
Frequency/pulse output
Measurement of: (optional via menu)
Frequency
Time constant
Pulse width
Active: Output mode
Passive: Output mode
Output mode
Relay
Load
Time constant/Hysteresis
Cut off: Low flow
Supply voltage and
power consumption
Internal counters (totalizers)
Measurement of
Display
Enclosure
Material
Mechanical vibration
Ambient temperature
CE-mark
Low voltage According to EN 60730
Enclosure
Material
Mechanical vibration
Ambient temperature
Supply voltage and power
consumption
SFIDK.PS.029.Q3.02
Individually galvanically isolated,
isolation voltage 500 V
Volume flow, sound velocity
0-20 mA or 4-20 mA
< 800 ohm
0.8-30 s adjustable
Individually galvanically isolated,
isolation voltage 500 V
Volume flow, sound velocity,
total volume, total mass
0-10 kHz
0.8-30 s adjustable
50 µs, 500 µs, 5 ms, 20 ms, 50 ms, 100 ms,
500 ms, 1 s, 5 s
24-30 V d.c./max. 25 mA, (50 µs to 5 s)
(50 ms E.Mech., max. 75 mA if F < Hz)
24-30 V d.c./max. 50 mA, (500 Hz to 10 kHz)
5-30 V d.c.
Max. current 200 mA
Output can be either active or passive
depending on electrical connection
Change-over relay (error indication,
flow direction, sound velocity limit)
42 V, 0.5 A
5 s/0.5 % F.S.O.
0-9.9 % F.S.O.
115-230 V a.c. +10% to −15%, 50-60 Hz,
10-20 VA
24 V d.c. +25/−15%, 24 V a.c. ±15%, 10 VA,
cable impedans < 10 ohm at 24 V
Two internal counters. Selectable uni- or
bidirectional counting (Net flow)
Total volume
Back-lit with alphanumerical text, 2 x 16 digits
for indication of: measured values, totalization,
settings, error codes and alarms
IP 67 to IEC 529
Fibre glass reinforced polyamide
2G 1-800 Hz sinusoidal in all directions
to IEC 68-2-6
Operation: −20 °C to +55 °C
−40 °C to +85 °C
Storage:
EMC CENELEC
Emission
EN 50081-1
IP 20 to IEC 529 and DIN 40050
Standard 19" insert in aluminium/steel
(DIN 41494)
1G 1-800 Hz sinusoidal in all directions
to IEC 68-2-6
Operation: +0 °C to +55 °C
−40 °C to +85 °C
Storage:
115/230 V a.c. +10% to −15%, 50-60 Hz,
10-20 VA
Terminal
connection
31 and 32
33 and 34
35 and 36
50, 51 and 52
54, 55 and 56
44, 45 and 46
PE, N and L
PE, N and L
PE, 1 and 2
Immunity
EN 50082-2
PE, N and L

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents