User Mode Functions - Canon imageFormula DR-9050C User Manual

Canon photo scanner user manual
Hide thumbs Also See for imageFormula DR-9050C:
Table of Contents

Advertisement

4.

User Mode Functions

The following functions are available in the User Mode.
■ Buzzer (Beeper) Control Setting
The beeper ("buzzer") sounds when you press the control
panel keys and when a scanning error occurs.
ON2: The beeper sounds when a scanner error occurs, and
when a control panel key is pressed.
ON1: The beeper sounds when a scanner error occurs.
OFF: The beeper never sounds.
■ Double-Feed Control Setting
Select whether double-feed detection is enabled when the
Count-Only mode is enabled. If you set DBL Feed Control
to [ON], double feeds are detected during feeding in the
Count-Only mode.
(See "Double-Feed Detection" on
p. 4-5.)
■ Staple Detection Setting
Select whether staple detection is enabled when the Count-
Only mode is enabled.
(See "Staple Detection" on p. 4-6.)
ON: Detects staples in the Count-Only mode.
OFF: Does not detect staples in the Count-Only mode.
■ Staple Detection Level Setting
Sets the staple detection sensitivity level.
[1] is the default setting, [2] provides higher sensitivity,
and [0] provides lower sensitivity.
■ Long Document Mode Setting
You can enable this mode to detect and scan document
pages up to 118.11" (3 m) long when the Auto Detection
page size setting is selected.
Setting" on p. 3-4.)
ON2: Automatically detects page sizes when scanning
documents up to 118.11" (3 m) long.
ON1: Automatically detects page sizes when scanning
documents up to 39.37" (1 m) long.
OFF: Automatically detects page sizes when scanning
documents up to 17.01" (432 mm) long.
Hint
Feeding a document longer the maximum detectable page size
for Auto Detection causes a paper jam indication, and transport
stops.
4-10
Chapter 4 Other Functions
(See "Long Document Mode

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents