AM-SEK / LIN-501C Quick Start Guide
Communicating with the Access Network
Local Connecting with AccessBase2000
After opening the AccessBase2000 application, go to the network
settings screen and set each active network to connect using the virtual
COM port number (COM2 - COM8) that was setup to communicate with
its LIN-501C module.
Local Connecting with AXNET
Create a Windows direct connect network when setting up for AXNET
communications. Be sure to select the virtual COM port number assigned
to the LIN-501C module for the "Communications Cable Between Two
Computers" setting. Be sure to configure the port speed to 38400 bps.
Remote Connecting with AccessBase2000
After opening the AccessBase2000 application, go to the network
settings screen and set each active network to connect using the virtual
COM port number (COM2 - COM8) that was setup to communicate with
the router's external IP address and module's public port number.
✓ NOTE: In existing installations, it is not recommended to
connect with AccessBase2000 remotely on a separate setup
PC. The installation's database in the local PC could get
overwritten, causing LOSS OF ALL CARDHOLDER DATA and
other programming! Always backup installation data!
Remote Connecting with AXNET
Create a Windows direct connect network when setting up for AXNET
communications. Be sure to select the virtual COM port number that was
setup to communicate with the router's external IP address and module's
public port number. Be sure to configure the port speed to 38400 bps.
After the network connection is made and connected, use an Internet
Web browser to connect to the AXNET panel.
LIN-501C General Specifications
✓ Note: LIN-501C Module is only available in the AM-SEK Kit and
is not sold separately.
Power: 12 VDC from plug-in power supply (included), also supports a
5 volt DC redundant input from an external power supply
Network Connection: 100BASE-T RJ-45 connector
Network Speed: Fast Ethernet 10/100 Mbps
Serial Connection: Male DB9 for connection with A2C/DB9 serial
cable (included)
Serial Port Speed: 38.4 Kbps
Mounting: DIN-rail or screw mounting
Dimensions (LIN‑501C Module): 3-1/2" W x 3-3/4" H x 1" D
Weight: 6-1/2 ozs.
Copyright © 2011 Linear LLC
All manuals and user guides at all-guides.com
Using Ping to Test IP Addresses
1. From the Windows START menu, select RUN.
2. Enter COMMAND (or CMD) into the OPEN: field and press OK. The
3. To test an IP address enter PING and the IP address.
4. If the Ping command displays "Request timed out." the IP address
5. If the Ping command displays replies from the IP address, the
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
- 4 -
DOS command prompt window will open.
is not currently used. The address can be assigned to a LIN-501C
module.
address is already being used by a device and cannot be assigned
to a LIN-501C module.
Serial Cable
LIN‑501C
Serial‑to‑Ethernet
Module
AM-SEK Kit Includes:
Software CD
& Quick Start
Guide
Power Adapter
231625 A

Advertisement

loading

Summary of Contents for Linear AM-SEK

  • Page 1 Guide LIN-501C General Specifications Power Adapter ✓ Note: LIN-501C Module is only available in the AM-SEK Kit and is not sold separately. Power: 12 VDC from plug-in power supply (included), also supports a 5 volt DC redundant input from an external power supply...
  • Page 2 All manuals and user guides at all-guides.com AM-SEK / LIN-501C Quick Start Guide General LIN-501C Module Configuration 11. Write the settings in the log sheet to document the access network module and note the modules address settings. 1. From the Windows START menu, select RUN.

This manual is also suitable for:

Lin-501c