Display Unit (Digital Indicator, Distance Indicator); Grounding; Wiring Check - Furuno DS-80 Installation Manual

Doppler speed log
Hide thumbs Also See for DS-80:
Table of Contents

Advertisement

2.5 Display Unit (Digital Indicator, Distance Indicator)

Use the cable assemblies MJ-A7SPF0009-020 and MJ-A6SPF0013-020 (supplied).
Connect the cable at the rear of the display unit, and fabricate the other end of the cable for
connection to the terminal box. Refer to the interconnection diagram at the end of this manual.
2.6

Grounding

This equipment uses pulse signals which may cause interference to other electronic equipments
It is strongly recommended to ground all cables referring to the guidelines below.
Separate all units as far as possible from radio equipment.
Do not run interconnection cables close to or near radio equipment or its cables.
Run the cables in the shortest path practical.
Ground all units with a copper strap or earth wire.
To joint copper straps, use solder cream for perfect contact.
2.7

Wiring Check

After the all wiring, make sure the toggle switches are set as below in the transceiver unit and
distribution box.
Tx toggle switch:
Upper
Power switch:
Upper (ON)
Transceiver unit DS-810,
inside arrangment
S1
ON
OFF
S1
ON
OFF
28
DIP Switch S1
KCP Board (65P6020)