Wiring Of Terminal Box - Furuno DS-80 Installation Manual

Doppler speed log
Hide thumbs Also See for DS-80:
Table of Contents

Advertisement

2.4

Wiring of Terminal Box

Fix the cables with the cable tie at the fixing plate. All cables except the power cable should be
fixed by the clamp with the armor.
Fabrication of TTYCY-2S
(for display unit and digital indicator/distance indicator)
Anticorrosive
sheath
TTYCYS-1
Cut vinyl sheath between armor and shield, and wind shield around armor and then lay cable so
armor is in the cable clamp.
20S0251 (for display unit, digital indicator/distance indicator)
Locate the fuse of the cable inside the terminal box.
Tape the drain wire, and fix the earth terminal in the terminal box.
Outer sheath should be fixed in the cable clamp.
65S1231 (for display unit, digital indicator/distance indicator)
Strip the outer sheath by 120 mm, and fasten it by the clamp. Attach the climp-on lug FV0.5-4 to
each core.
Within 120 mm
Shield
Armor
Remove the shield between the fixing plate
and terminal box.
Fabrication of cable TTYCY-3S
Anticorrosive
Sheath
Wind the shield.
Armor
1
2
15
20
FV2-M4
within 120
27
FV2-M4

Advertisement

Table of Contents
loading