Others - Stanley PB2500 Instruction Manual

Battery power tool
Hide thumbs Also See for PB2500:
Table of Contents

Advertisement

Symptom
Tool does not show
1. Judgement range setting is not
NOK, even if it sets
correct
incorrect rivet
Screen does not
show process curve
2. Rivet break load is small, it is under
or does not show
3,000N
correctly.
Tool does not count
1. Rivet break load is too small, it is
correctly
under 2,000N
(does not count or
2. Riveting cycle is too fast.
counts even if it
Pulled trigger before judgement.
does not set rivet).
Rivets / Charge is
1. Smart function is turned on.
low.
2. Battery is not fully charged
3. Battery is defective
*Contact Stanley Engineered Fastening local service center, if you cannot recover troubles from trouble shooting
above.

Others

 "Manufacturer" in "13. Others" menu is for administration in Stanley Engineered
Fastening", so do not use this menu.
Cause
2. Judgement range setting is too largel
3. Not fasten 5 rivets in average mode
4. There is a problem in tool.
5. Trigger module is defective.
6. Smart function is turned off.
1. Smart function is turned off.
4. Setting data are broken
Set judgement range correctly
Set appropriate range
Fasten 5 rivets, if it has an error,
do it again
Remove cause of issue or contact
local service center
Replace motor & module
assembly or contact local service
center
No NOK judgement if smart
function is turned off.
If needed, turn on smart function
Turn on smart function
Turn off smart function, if low
break load rivets are used
Counter function cannot be used
in very low break load rivet.
Pull trigger for next riveting after
judgement.
Restore to factory settings
Rivets / Charge decreases, if
smart function is turned on. Turn
on/off smart function as needed.
Check battery charge level and
charge battery
Replace battery
- 33 -
Remedy
Page
P15, 16
P15, 16
P.15
-
-
P.14
P.14
P.8, P14
P.8
-
P31
P.14
P.31 or
Refer to
tool
manual
-

Advertisement

Table of Contents
loading

Table of Contents