Korg AX1000G Service Manual page 11

Modeling signal processor
Hide thumbs Also See for AX1000G:

Advertisement

AX1000G test mode
1. The test mode starts when plugging the AC adaptor while pressing
[ANBIENCE] and [NR-PROG-LEVEL].
2. Set the pedal to MIN. and confirm that the all the LEDs of [DRIVE-AMP],
[CABINET], [MODULATION], [PEDAL] and [AMBIENCE] light up. In case any
LEDs do not light up, turn the semi-fixed VR at the rear panel so that all the
LEDs light up.
3. After confirming it, press [ > ] to go to the next test.
4. Press the switches indicated in the LCD in turn and confirm
the functions. The order of the switches to be pressed is as
follows:
[1], [2], [3], [4], [BANK UP], VR-PEDAL, [DRIVE-AMP], [CABINET],
[MUDULATION], [PEDAL], [ANBIENCE], [NR-PRG-LEVEL], [RENAME],
[WRITE], [EXIT], [<], [UP], [DOWN],[>]
5. Confirm all the characters for the LCD light up and press [ > ].
6. Confirm all the characters for the LCD disappear and press [ > ].
7. Confirm 2 patterns of the characters for the LCD light up and
press [ > ].
8. Confirm the value of the LCD changes when turning the VR which is
pointed out with the twinkle of the LED to MAX , then to MIN.
9. Set the VR which is pointed out with the twinkle of the LED to center and
press [ > ].
10. Set the pedal to MAX and press [ > ].