Functions and device responses

5.4 Learn run button

5.4
Learn run button
The learn run button (S501) combines the functions of the automatic learn and test run, and
the option of opening and closing the door from the controller.
The learn and test run is activated by pressing the learn run button for more than five
seconds.
The door can be moved by pressing the learn run button briefly for between 0.1 and two
seconds.
The inputs "Open" and "Close" must not be activated:
• First button press for between 0.1 and 2 seconds in normal or initial operation → door
opens until it reaches the "OPEN" end position, and remains stationary with the average
value of the PWM signal.
• If the button is pressed for between 0.1 and 2 seconds again before the door has
completely opened, the door stops and remains stationary with the average value of the
PWM signal.
• When the button is pressed again for between 0.1 and 2 seconds in normal or initial
operation → door closes until it reaches the "CLOSED" end position, and remains
stationary with the average value of the PWM signal.
• If the button is pressed for between 0.1 and 2 seconds again before the door has
completely closed, the door stops and remains stationary with the average value of the
PWM signal.
• The next button press opens the door again.
• If no buttons are pressed for a period longer than 10 seconds, the next button press for
between 0.1 and 2 seconds always opens the door.