Insert tweezers
(1)-1
(1)-1
or the like.
BARREL1 CAP
(1)-2
FRONT CAP
(1)-3
BARRIER PLATE
(1)-5
BARRIER DRIVE
PLATE
(1)-7
BARRIER OPEN
SPRING
(1)-8
BARRIER DRIVE
RING
2.13 OPTICAL UNIT
(1) OPTICAL UNIT
1. Remove the BARREL1 CAP by inserting tweezers or the like into its groove.
2. Remove the FRONT CAP.
3. Remove the BARRIER PLATE (2 pieces).
4. Remove the two claws and remove the BARRIER BASE.
5. Remove the BARRIER DRIVE PLATE.
6. Remove the BARRIER CLOSE SPRING.
7. Remove the BARRIER OPEN SPRING.
8. Remove the BARRIER DRIVE RING.
NOTE1 (Assembling)
NOTE2 (Assembling)
NOTE3 (Assembling)
NOTE2 (Assembling)
BARRIER PLATE
(1)-3
(1)-4
BARRIER BASE
(1)-6
BARRIER
CLOSE SPRING
Fig. 3-15 OPTICAL UNIT
Apply the voltage (DC 2.5V) across the motor terminal to drive the motor until the
motor stops and the BARREL is full housed.
Attach the DIABOND to the FRONT CAP.
Attach the HANARL to the BARRIER BASE.
3-15
CHAPTER 3. REPAIR INSTRUCTION
Remove the claws
DIABOND
(1633G)
NOTE3 (Assembling)
HANARL
(OIL)
NOTE1 (Assembling)
DC2.5V
DC2.5V
(1)-4
HANARL
(OIL)