RESETTABLE THERMAL SWITCH REPLACEMENT
Step 1.
Rotate the knob of combination thermostat/gas valve to the "OFF" position.
Step 2.
Remove the outer jacket door.
Step 3.
Disconnect the wire leads from the resettable
thermal switch.
Step 4. Remove the resettable thermal switch from the
inner door (Phillips screwdriver).
Step 5. Put new resettable thermal switch in place. Be sure contact surface of resettable thermal switch
and inner door are free of any debris. Secure resettable thermal switch into place using screws
from Step 4. DO NOT OVER TIGHTEN SCREWS.
Step 6.
Reconnect wire leads from combination thermostat/gas valve to resettable thermal switch.
NOTE: Wire terminations are interchangeable with either resettable thermal switch connection.
Step 7.
Replace the outer jacket door.
Step 8.
To resume operation, follow the instructions located on the lighting instruction label or the lighting
instruction located in the Installation and Operation Manual.
38