14.3. Assembly on transom window

Aside the drawing of specific application using
accessories provided. For different mountings, please
contact manufacturer.
Before starting, check that there are at least two
mechanical compass safety stops or other form of
stops connected to the frame, and ensure that the
stops can prevent any accidental fall of the window.
Your safety is at hand.
Pencil in an "X" over the centre line of the window frame
A.
(Fig. 7).
Select the correct form of brackets (Fig. 8).
B.
Attach the template to the window frame (fixed part) and
C.
line axis up with the centre line "X" traced earlier (Fig. 9).
Warning: for window frames not on the same plane, cut
the part of the template coloured in grey and fix this to
the moveable part of the window frame, taking care to
keep it in the same position.
Bore holes in the window frame at the points indicated
D.
on the template (Fig. 10).
Assemble the two brackets with the distancer (to help
E.
position correctly. Once it has served its purpose it can
be removed). Mount the supports onto the frame with the
appropriate screws provided. Check that everything is
aligned both horizontally and vertically.
Mount the bracket for outward opening windows onto the
F.
moveable part of the frame in accordance with the
markings indicated on the template.
Complete assembly of the chain terminal with the safety
G.
clip inserted onto the provided pin Ø4x32 in median
position (see fig. 11).
Mount the actuator onto the brackets by inserting the two
H.
openings at each side onto the corresponding pins on
the brackets.
Rotate the actuator 90°, bring the chain terminal up to
I.
the bracket and insert the pin into the opening on the
bracket. Insert the safety clip into the bracket.
Check that the exit on the chain is perfectly aligned with
J.
the bracket. If the chain is not aligned with the bracket,
loosen the fixing screws and reposition the bracket
correctly.
Check all electrical connections with the diagram on the
K.
label attached to the lead and in conformity to indications
on chapter 9 – Electrical connection.
Carry out a complete check of opening and closure of
L.
the window. Once the closure phase has been
completed, check that the window frame is completely
closed by checking the pressure on the weather strips.
Inward application – transom
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
window
Page 15