Electrical Installation - Vaillant AutoCompact VSC D 4 Series Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

5 Installation
A
1.
Insert a screwdriver into the slot between the test
points.
2.
Carefully exert pressure on the screwdriver (A).
3.
Turn the connector anti-clockwise (B) as far as it will go
and then remove it by pulling it upwards (C).
4.
Insert the new connector. In doing so, pay attention to
the latching lugs.
5.
Turn the connector clockwise until it clicks into position.
5.6.3
Information and specifications for installing
the B23P
Pipe lengths in the B23P installation (→ Page 42)
The flue gas system must at least correspond to the classi-
fication T 120 P1 W 1 in accordance with EN 1443.
The maximum pipe length (straight pipe only) corresponds to
the maximum permitted flue gas pipe length without any el-
bows. If elbows are used, the maximum pipe length must be
reduced in accordance with the dynamic flow characteristics
of the elbows. Elbows must not be connected directly after
one another as this method dramatically increases pressure
losses.
In particular, if the flue pipe is installed in cold rooms or out-
side of the building, the freezing point on the surface of the
inside of the pipe may be reached. A proven design in ac-
cordance with EN 13384-1 for a maximum boiler load at a
flue gas temperature of 40 °C must be used to prevent this
problem. The product must not be connected to a cascade
flue gas system that is being used by other units.
Observe the applicable international, national and local
regulations for flue gas systems, in particular for installa-
tions in living rooms. Inform the operator how to correctly
operate the product.
5.7

Electrical installation

Only qualified electricians may carry out the electrical install-
ation.
Danger!
Risk of death from electric shock!
Touching live connections may cause serious
personal injury. Since mains connection ter-
minals L and N remain live even if the on/off
button is switched off:
Switch off the power supply.
Secure the power supply against being
switched on again.
16
C
B
5.7.1
5.7.1.1 Opening the electronics box
1.
2.
3.
4.
5.7.1.2 Closing the electronics box
1.
2.
3.
Installation and maintenance instructions auroCOMPACT 0020233500_01
Danger!
Risk of death from electric shock as a res-
ult of an improper electrical connection!
An improper electrical connection may neg-
atively affect the operational safety of the
product and result in material damage or per-
sonal injury.
Only carry out the electrical installation if
you are a trained competent person and
are qualified for this work.
Observe all applicable laws, standards
and directives in the process.
Earth the product.
Opening/closing the electronics box
Remove the front casing. (→ Page 11)
C
A
2
1
Hinge the electronics box (1) forwards.
Undo the four left- and right-hand clips (3) from the re-
tainer.
Fold up the cover (2).
Close the back panel (2) by pressing downwards on the
electronics box (1).
Ensure that all four clips (3) audibly click into the re-
tainer.
Fold the electronics box upwards.
3
B
A

Advertisement

Table of Contents
loading