Room Sealed Flue Fitting - Worcester GREENSTAR OILFIT Instruction Manual

Conventional flue & room sealed flue
Table of Contents

Advertisement

4
A
B
5
K
14

ROOM SEALED FLUE FITTING

C
25mm
F
3.3mmO x2
ROOM SEALED FLUE FITTING
J
F
K
F
GREENSTAR OILFIT INSTALLATION INSTRUCTIONS
4
Where applicable, loosely fix support
bracket/s (J) to support the weight.
Push-fit flue (F) into elbow (K).
NOTE: Camray 25/32 models using a vertical
terminal, the 80/125 to 100/150mmO vertical
adaptor MUST be fitted vertically at the lowest
point of the vertical section of the flue. Failure
to fit the adaptor vertically will cause the
condensate pool within the flue and will
adversely affect the flue's performance.
Secure flue support bracket/s (J), where
used.
5
Drill two holes with the drill provided (180°
apart if possible) through the outer flue
elbow (K) into the outer flue tube (F) taking
care NOT to drill the inner flue tube and
secure with screws supplied.
8 716 106 261b (01/07)