Room Sealed Flue Options - Worcester GREENSTAR OILFIT Instruction Manual

Conventional flue & room sealed flue
Table of Contents

Advertisement

HORIZONTAL TERMINAL OPTIONS:
L=140-390mm
L
A
L=4000mm
L
A
+
B
125mmO x4
*
L=3000mm
L
A
+
B
125mmO x3
+
C
L=3000mm
L
A
+
B
125mmO x3
+
D
D
L=3000mm
A
+
L
B
125mmO x3
+
C
GREENSTAR OILFIT INSTALLATION INSTRUCTIONS
8 716 106 261b (01/07)
L=2000mm
*
A
+
B
125mmO x2
+
C
x2
*
Greenstar Danesmoor Kitchen
Greenstar Danesmoor Utility
Greenstar Camray Kitchen
Greenstar Camray Utility
Greenstar Camray System
*
*from the boiler casing, (exclude the 120mm of terminal extending beyond the building).
**from the boiler casing (the vertical kit elbow is ignored when calculating the flue length)
A
B
*
A - Horizontal terminal
B - Straight flue extension
C - Flue bend 90°
D - Flue bend 45°
E - Vertical Terminal Kit (incl. 90° elbow)

ROOM SEALED FLUE OPTIONS

*
L
The
components used and the maximum flue
length (L) for each flue configuration.
• To achieve the maximum flue legth (L), a flue
• Only the flue terminal or straight flue
• The flue terminal end can be fitted from the
Calculating the flue length:
Measure the total flue length required, noting
that the maximum straight flue length including
the terminal is:
Appliance
12/18, 18/25 & 25/32
12/18, 18/25 & 25/32
Greenstar Heatslave
12/18, 18/25 & 25/32
12/18 & 18/25
12/18 & 18/25
12/18 & 18/25
Then reduce the total straight flue length for
each extra flue bend by:
1000mm for each 90°
500mm for each 45°
Flue Extension Lengths:
Horizontal & Vertical 1000mm overall length.
Effective length when engaged into sockets
C
D
within the flue run is 950mm
E
Flue Terminal Lengths:
Horizontal 80/125mmO: 720mm
Vertical 80/125mmO: 1080mm + cage
Vertical 100/150mmO: 1290mm + cage
*
diagrams
(opposite)
section will have to be reduced in legth.
extensions can be reduced in length by
cutting.
inside or outside of the building.
IMPORTANT:
All horizontal sections must rise away from
the boiler by 52mm per metre (3°) to allow
the condensate to drain back to the boiler.
Maximum flue length (L)
(mm)
Model
Horizontal
Vertical
terminal
terminal
4000*
6000**
4000*
6000**
4000*
6000**
4000*
8000**
4000*
-
25/32
-
8000**
4000*
8000**
4000*
-
25/32
-
8000**
4000*
8000**
4000*
-
25/32
-
8000**
to outside wall.
ROOM SEALED FLUE OPTIONS
show
the
Flue
diameter
(mm)
80/125
80/125
80/125
80/125
80/125
100/150
80/125
80/125
100/150
80/125
80/125
100/150
9