3.
Fabricate a flashing having a 16-1/2" diameter hole centered
over chimney end with a 2" collar around hole (see Figure 22).
Attach noncombustible spacers at each corner and place flash-
ing over chase.
4.
Secure flashing through sides with 8-penny nails or sheet rock
screws.
5.
Place galvanized sleeve through hole in flashing and around last
section of chimney (see Figure 23).
6.
Place termination cap over opening and slip stainless steel inner
pipe into stainless steel chimney section. Lower termination as-
sembly until cap rests evenly over flashing hole. Secure cap at
each corner with sheet metal screws (see Figure 24).
16-1/2" Diameter
28 Gauge
Galvanized Steel
Figure 22 - Constructing Chase Top Flashing
1" Spacer
Note: Do Not Seal
Ventilation Openings
36"
(915 mm)
Min.
Galvanized Sleeve
2" (51 mm) Min.
Figure 23 - Installing Termination Cap
14
INSTALLATION Continued
2" Collar
Note: Do Not Seal
Ventilation Openings
Figure 24 - Securing Termination to Chase Top Flashing with Sheet
ROUND TOP TERMINATIONS INSTALLATION RLT-12D, AND
RLT-12HT
As Required
1.
2.
3.
Termination Cap
Screw
3"
(762 mm)
(77 mm)
Min.
SuperiorFireplaces.us.com
Termination
Sheet Metal Screw
Metal Screws
Construct chase as illustrated in Figure 25. Note: The shortest
vertical side must be at least 30" high and the minimum inside
dimension must be at least 19" as shown in Figure 25.
Add pipe sections to chimney system as outlined in fireplace
installation instructions until the last piece of chimney is a
minimum of 6" above chase top (see Figure 25).
Fabricate a flashing having a 16-1/2" diameter hole centered over
chimney end with a 2" collar around hole (see Figure 26, page 15).
(483 mm) Min.
30"
Min.
Figure 25 - Constructing Chase
1" Noncombustible
Spacer
Chase Top
1" Space
1/4" Screen
Chase Facia
19"
6" (153 mm) Min.
126601-01_J

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents