Operation - Superior Fireplaces VCM3026ZTP Assembly, Installation And Operation Instructions

Unvented (vent-free) compact fireplace
Table of Contents

Advertisement

Equipment
Shutoff Valve
Propane/LP
Supply Tank
Figure 26 - Checking Gas Joints for
Propane/LP Gas (Shown with Optional
Mantel)
Equipment
Shutoff Valve
Gas Meter
Figure 27 - Checking Gas Joints for
Natural Gas (Shown with Optional Mantel)
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
126871-01A-01
INSTALLATION
Continued

OPERATION

www.SuperiorFireplaces.US.com
PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure
25, page 18).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of fireplace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to thermostat gas valve (see Fig-
ures 26 and 27). Apply a noncorrosive
leak detection fluid to gas joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Light fireplace (see Operation). Check all
other internal joints for leaks.
7. Turn off fireplace (see To Turn Off Gas to
Appliance, page 21).
8. Replace front panel.
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don't try to repair it, call a quali-
fied service technician or gas supplier.
Force or attempted repair may result in
a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
LIGHTING
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vcm3026ztn

Table of Contents