Recirculating; Attach Mounting Plate To Wall; Preparation Of Top Cabinet - GE ZSA1201 Installation Instructions Manual

Above the cooktop oven
Table of Contents

Advertisement

Available languages

Available languages

RECIRCULATING

C
INSTALLATION OVERVIEW
C1. Attach Mounting Plate to Wall
C2. Prepare Top Cabinet
C3. Adjust Blower
C4. Mount the Oven
C5. Install Charcoal Filter (not supplied)
C1
ATTACH THE MOUNTING
PLATE TO THE WALL
Attach the plate to the wall using toggle bolts. At
least one wood screw must be used to attach the
plate to a wall stud.
1
Remove the toggle wings from the bolts.
2
Insert the bolts into the mounting plate through
the holes designated to go into drywall and
reattach the toggle wings to
To use toggle bolts:
Spacing for
Toggles More Than
Wall Thickness
Toggle Wings
Mounting
Toggle
Plate
Bolt
Wall
49-40650-5
Installation Instructions
(Non-Vented Ductless)
3 4
Bolt End
3
Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall to
mount the plate.
NOTE: Before tightening toggle bolts and wood
screw, make sure the tabs on the mounting plate
touch the bottom of the cabinet when pushed
flush against the wall and that the plate is properly
centered under the cabinet.
CAUTION
Be careful to avoid pinching
fingers between the back of the mounting plate
and the wall.
4
Tighten all bolts. Pull the plate away from the wall
to help tighten the bolts.
C2
USE TOP CABINET TEMPLATE FOR

PREPARATION OF TOP CABINET

You need to drill holes for the top support screws and
a hole large enough for the power cord to fit through.
• Read the instructions on the TOP CABINET
TEMPLATE.
• Tape it underneath the top cabinet.
• Drill the holes, following the instructions on the
TOP CABINET TEMPLATE.
CAUTION
Wear safety goggles when
drilling holes in the cabinet bottom.
19