Fujitsu AOG30KATA Series Service Instruction page 51

Split type room air conditioner
Table of Contents

Advertisement

Trouble shooting 8
INDOOR UNIT Error Method:
Connection unit number error (Indoor
unit in Wired remote controller system)
Detective Actuators:
Wired remote controller ( 2-Wire )
Indoor unit Controller PCB circuit
Forecast of Cause :
1. Wrong wiring / Number of I.U, RC in RCgroup 2. Indoor unit controller PCB defective
Check Point 1 : Wire installation
Wrong number of connecting indoor unit
OK
Check Point 2 : Check Indoor unit controller PCB
Check if controller PCB damage
Check if controller PCB and check the Error after setting remote controller address
Indicate or Display:
Error code : 29
Detective details:
When the number of connecting indoor units are out of specified rule.
02-09
Outdoor unit :
Mode Error L1 L2
L3
L4
2
5
15
: Light OFF
: Light ON
n : n times blinking
L5
L6

Advertisement

Table of Contents
loading