Fan Control; Indoor Fan Control - Fujitsu AOG30KATA Series Service Instruction

Split type room air conditioner
Table of Contents

Advertisement

3. Fan control

Tr: Room temperature
Ts: Setting temperature

3-1. Indoor fan control

¢ Fan speed
Indoor fan speed is defined as below.
Operation mode
Heating
Cooling/Fan
Dry
*1: Fan mode only
*2: Cooling mode only
¢ Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
¢ Cooling operation
Switch the airflow AUTO, and indoor fan motor will run according to room temperature, as below.
On the other hand, if switched in HIGH—QUIET, indoor motor will run at a constant airflow of COOL
operation modes QUIET, LOW, MED, HIGH as shown in "Fan speed" above.
Airflow change over (Cooling: Auto)
2°C
3-1. Indoor fan control
Fan mode
AUXG30KRLB
HIGH
570
MED+
530
MED
510
LOW
470
QUIET
420
Cool air
300
prevention
S-LOW
270
HIGH
570
MED
510
LOW
470
QUIET
420
Soft quiet
300*
S-LOW
270*
X zone: 420
J zone: 420
Tr - Ts ≥
2°C
> Tr - Ts ≥
1°C
1°C > Tr - Ts
When room
temperature drops
Speed (rpm)
AUXG36KRLB
640
600
560
510
430
300
270
640
560
510
430
1
1
300*
2
2
270*
X zone: 430
J zone: 430
Tr - Ts ≥
HIGH mode
2.5°C
MED mode
1.5°C > Tr - Ts
LOW mode
When room
temperature rises
- (04-12) -
AUXG45KRLB
AUXG54KRLB
670
690
630
680
590
630
530
570
470
480
300
300
270
270
670
690
590
630
530
570
470
480
1
300*
300*
2
270*
270*
X zone: 470
X zone: 480
J zone: 470
J zone: 480
2.5°C
> Tr - Ts ≥
1.5°C
1
2
3. Fan control