Model: AOYG54KATA
Fan speed is defined by outdoor temperature and compressor frequency.
Fan step
13
12
11
10
9
8
7
6
5
4
3
2
1
S-HIGH
• When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed.
• When the compressor frequency decreases, the outdoor fan speed also changes to the lower
speed.
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,040 rpm
3-2. Outdoor fan control
Cooling or dry
970
900
830
760
690
620
550
480
420
360
300
240
200
—
- (04-17) -
Unit: rpm
Heating
—
—
—
1,040
880
800
720
630
520
440
360
270
200
1,040