Installation and maintenance instructions
Publisher/manufacturer
Vaillant GmbH
Berghauser Str. 40
D-42859 Remscheid
Tel. +49 21 91 18‑0
Fax +49 21 91 18‑2810
info@vaillant.de
www.vaillant.de
eloSTOR plus
VEH 10/7 U
AT, DE

Advertisement

Table of Contents
loading

Summary of Contents for Vaillant eloSTOR plus VEH 10/7 U

  • Page 1 Installation and maintenance instructions eloSTOR plus VEH 10/7 U AT, DE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18‑0 Fax +49 21 91 18‑2810 info@vaillant.de www.vaillant.de...
  • Page 2: Table Of Contents

    Contents Contents Safety ..............3 Intended use ............3 General safety information ........3 Regulations (directives, laws, standards) ....4 Notes on the documentation ......5 Observing other applicable documents ....5 Storing documents..........5 Applicability of the instructions ......5 Product description..........
  • Page 3: Safety

    Safety 1 Safety General safety information 1.2.1 Risk caused by inadequate Intended use qualifications There is a risk of injury or death to the user or The following work must only be carried out others, or of damage to the product and other by competent persons who are sufficiently property in the event of improper use or use qualified to do so:...
  • Page 4: Regulations (Directives, Laws, Standards)

    1 Safety ▶ If there are leaks in the water pipe 1.2.4 Material damage due to unsuitable installation surface between the product and draw-off points, close the cold water stop valve immedi- The installation surface must be even and ately. have sufficient load-bearing capacity to sup- ▶...
  • Page 5: Notes On The Documentation

    Notes on the documentation 2 Notes on the documentation Information on the identification plate Information on the Meaning Observing other applicable documents identification plate ▶ You must observe all the operating and installation in- Serial number For identification purposes; 7th to 16th structions included with the system components.
  • Page 6: Product Dimensions

    5 Installation Product dimensions 3/8" 3/8" Use the appropriate fixing material to secure the product to the wall as shown in the illustration. Conditions: The load-bearing capacity of the wall is sufficient, The fixing material may be used for the wall ▶...
  • Page 7: Installing The Safety Group

    Installation 5 ◁ Filling the product Regularly actuate the safety assembly in order to prevent a blockage caused by scale depositions. Open the cold water stop cock. You must install a pressure valve assembly. Fill the domestic hot water cylinder. Attach heat insulation to the pipelines if they are at risk ◁...
  • Page 8: Start-Up

    6 Start-up ◁ Earth connection Heating coil You can set the target temperature to either 40 °C, 60 °C or 80 °C. Overheating protection Remove the temperature selection knob (1). Plug the mains plug into an earthed socket outlet. Remove the adjusting ring (2) for the temperature se- ◁...
  • Page 9: Inspection And Maintenance 8

    Inspection and maintenance 8 ▶ Removing/installing the product casing If you require spare parts for maintenance or repair work, use only the spare parts that are permitted for the product. Inspection and maintenance Observing inspection and maintenance intervals Proper regular inspections (once a year) and maintenance (depending on the result of the inspection, but at least once every two years) combined with the exclusive use of genuine spare parts are decisive factors in ensuring smooth opera-...
  • Page 10: Checking The Magnesium Protection Anode

    ◁ The metal vessel must always be earthed. Der flächendeckende Kundendienst für ganz Österreich ist täglich von 0 bis 24 Uhr erreichbar. Vaillant Kundendienst- techniker sind 365 Tage für Sie unterwegs, sonn- und feier- tags, österreichweit. Applicability: Germany Auftragsannahme Vaillant Kundendienst: 021 91 5767901 Position the temperature sensor in its installation site.
  • Page 11: Appendix

    Appendix Appendix Technical data Technical data – General VEH 10/7 U Product type Direct electric do- mestic hot water cyl- inder with system for supplying one or more draw-off points. Type of installation Setting up below the work surface Inside of the cylinder Enamelled steel Operating mode Single-circuit unit...
  • Page 12 0020244342_01 0020244342_01 05.04.2017 Supplier Vaillant Deutschland GmbH & Co.KG Berghauser Str. 40 D-42859 Remscheid Telefon 021 91 18‑0 Telefax 021 91 18‑2810 Auftragsannahme Vaillant Kundendienst 021 91 5767901 info@vaillant.de www.vaillant.de Vaillant Group Austria GmbH Clemens-Holzmeister-Straße 6 1100 Wien Telefon 05 7050 Telefax 05 7050‑1199 Telefon 05 7050‑2100 (zum Regionaltarif österreichweit, bei Anrufen aus dem Mobilfunknetz ggf. abweichende Tarife - nähere Information erhalten Sie bei Ihrem Mobilnetzbetreiber)