PROGRAMMING MODE -
Diagnostic tests :
This program has been added for testing the dryer and detecting errors.
Entering the test mode
Data Name
1. Entering programming mode
Entering
the test mode
2. WHITES AND COLORS
3. START
1 1
Pressing the START button cycles to the next test function.
Number of times the START
button is pressed
None
1 time
2 times
3 times
4 times
5 times
6 times
During check, if the door is open.
During check, if the door is closed
Note
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
1 4
(display)
Button
Display
Checking point
Check the version and code of machine.
■ ELECTRIC TYPE : DO:OE
■ GAS TYPE : US:Og
Motor runs.
■ ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2700W)
■ GAS TYPE: GAS valve runs.
Motor + Valve
■ ELECTRIC TYPE: Heater runs.
Motor + Heater 1 +Heater 2 (5400W)
■ GAS TYPE: GAS valve runs.
Motor+Valve
LED & KEY CHECK
Press WHITES AND COLORS button.
Press PERMANENT PRESS button.
Press DELICATES button.
Test ends.
Door switch
(Motor & Heater Off, Buzzer beeps seven
times)
Test goes back at step 2.
(Motor on & Heater Off)
Test Mode
Push and hold the WHITES AND COLORS and DELICATES at the same time.
After that push PERMANENT PRESS button for 3 times. Push START button.
Press the WHITES AND COLORS button.
Then
appears in the display.
Enter the diagnostic test mode.
LqC 1
Version and code of machine (All LED on)
Display DO:OE or DO:Og and EU:XX
alternately. XX is the version number.
Measured moisture value (70~239)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Version and code of machine
LqC1
dE
(The door is open. Please close the door
completely)
Measured moisture value (70~239)
Description
Display

Advertisement