7-INSTALLATION

7.1 Operating Conditions

(See Specifi cations).
7.2 Space Requirements for Machine Operation
and Maintenance Work
Minimum distance from wall (Figure 7-1):
A = 1000mm.
B = 700mm.
Minimum height = 2700mm.
Figure 7-1

7.3 Tool Kit Supplied with the Machine

A tool kit containing some tools are supplied
with the machine. These tools should be
adequate to set-up the machine, however,
other tools supplied by the customer will be
required for machine maintenance.
WARNING
• To reduce the risk associated with
mechanical and electrical hazards:
− Allow only properly trained and
qualifi ed personnel to operate and
this equipment.
WARNING
To reduce the risk associated with
muscle strain:
Use the appropriate rigging and
material handling equipment when
lifting or repositioning this equipment.
Use proper body mechanics when
removing or installing taping heads
that are moderately heavy or may be
considered awkward to lift.
200a3-NA
Figure 7-2
7.4 Machine Set-Up / Bed Height
Adjust machine bed height. The case sealer is
equipped with four (4) adjustable legs that are
located at the corners of the machine frame. The
legs can be adjusted to obtain different machine
bed heights (See Specifi cations).
Refer to Figure 7-3 and set the machine bed height
as follows:
1. Raise and block up the machine frame to allow
adequate leg adjustment.
2. Loosen, but do not remove, two (2) M8 x 1.25mm
socket head screws in one leg (use M6 hex
wrench). Adjust the leg length for the desired
machine bed height. Retighten the two screws
to secure the leg. Adjust all four (4) legs equally.
M8 x 1.25mm
Socket Head
Screws
Adjustable
17
Leg
Figure 7-3