Factory Reset; Step 1: Uninstall Fortisiem Application; Step 2: Reinstall Fortisiem Application; Upgrading Fortisiem Collector - Fortinet FSM-500F Configuration Manual

Table of Contents

Advertisement

Appliance Setup

Factory Reset

Follow the steps below to perform factory reset on FortiSIEM FSM-500F.

Step 1: Uninstall FortiSIEM application

1. Connect FortiSIEM device using VGA or Console port.
2. Login as 'root' user with password 'ProspectHills'.
3. To check the available FortiSIEM commands, run get.
4. To uninstall FortiSIEM, run execute fsm-clean.
This script will uninstall FortiSIEM Collector.

Step 2: Reinstall FortiSIEM application

1. Power on the hardware.
2. Login as 'root' user with password 'ProspectHills'.
3. To check Hardware status and RAID information, run diagnose hardware info.
Note: RAID Information is NOT applicable to FSM-500F model.
4. To install FortiSIEM Collector, run 'execute factoryreset'.
Note: This script takes 5 minutes to complete FortiSIEM Collector installation.
Follow the steps under

Upgrading FortiSIEM Collector

For upgrading FortiSIEM Collector, refer to the

Appliance Re-image

Ensure that the following prerequisites are met before re-imaging FortiSIEM.
Hardware
Peripherals
USB Keyboard
l
USB Mouse
l
VGA Monitor
l
USB Thumbdrive
4 GB Thumbdrive (for Linux installation)
l
8 GB Thumbdrive (for FortiSIEM appliance
l
image)
FortiSIEM 6.3.1 500F Collector Configuration Guide
Fortinet Technologies Inc.
Appliance Setup
to configure FSM-500F.
Upgrade Guide.
Software
Ubuntu Desktop Setup Files
l
Rufus (Bootable USB Utility)
l
FortiSIEM Appliance Image
l