Multiple Heat Pump Installation; Physical Data - 30Rq - Carrier AQUASNAP 30RQ Installation, Operation And Maintenance Instructions

Table of Contents

Advertisement

3.3 - Multiple heat pump installation

NOTE: If the walls are higher than 2 m, contact the factory

4 - PhYsICal DaTa - 30RQ

30RQ
Nominal cooling capacity*
Total power input, cooling mode*
Nominal heating capacity**
Total power input, heating mode**
sound levels 10
W†
-12
Unit with Euro Pack option
Standard unit
Operating weight***
Standard unit with Euro Pack option
Standard unit with Euro Pack option and high-
pressure dual-pump hydronic module option
Unit without options****
Refrigerant
Circuit A
Circuit B
Compressors
Circuit A
Circuit B
No. of control stages
Minimum capacity
Control
air heat exchangers
Fans
Quantity
Total air flow
r/s
Water heat exchangers
Water volume
Max. water-side operating pressure
without hydronic module
hydronic module (option)
Water pump
Quantity
Expansion tank volume
Max. water-side operating pressure
with hydronic module
Water connections without hydronic module
Connections
Outside tube diameter
Water connections with hydronic module
Connections
Outside tube diameter
*
Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C, water heat exchanger fouling
factor 0.000018 m
K/W (rounded values, for information only).
2
**
Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 40°C/45°C, outside air temperature 7°C, 87% rh (rounded values, for
information only).
*** Weights are for guidance only. To find out the unit refrigerant charge, please refer to the unit name plate.
**** Standard unit: Base unit without Euro Pack option and hydronic module.
In accordance with ISO 9614-1 and Eurovent certified (rounded values, for information only).
10
A
B
B
B
B
1500
262
kW
243
kW
98
kW
273
kW
95
dB(a)
89
91
kg
2619
kg
2864
kg
2429
R-410A
kg
27
kg
27
Hermetic scroll 48.3 r/s
2
2
4
%
25
PRO-DIALOG Plus
Grooved copper tubes and aluminium fins
Axial FLYING BIRD 4 with rotating shroud
4
l/s
18056
15.7
15.7
Direct-expansion, two circuits, shell-and-tube
l
110
kPa
1000
Pump, Victaulic screen filter, safety valve, expansion tank, pressure gauge, purge valves (water and air) and
water flow control valves
Centrifugal, monocell, 48.3 r/s, low or high pressure (as required), single or dual pump
1
l
50
kPa
400
Victaulic
in.
4
mm
114.3
Victaulic
in.
4
mm
114.3
B
B
In case of multiple heat pumps (up to four units), the respective clearance
between them should be increased from 1500 to 3000 mm for the side space
requirement.
If necessary, add the required clearances for water heat exchanger tube or coil
removal.
302
342
372
275
310
331
106
122
125
307
344
364
110
123
126
90
90
91
92
92
93
3285
3481
3544
3590
3786
3889
3045
3241
3284
41
41
53
27
27
32
3
3
4
2
2
2
5
5
6
18
20
15
5
5
6
22569
22569
27083
15.7
15.7
15.7
110
125
113
1000
1000
1000
1
1
1
80
80
80
400
400
400
4
4
6
114.3
114.3
168.3
4
4
5
114.3
114.3
139.7
A
B
B
1500
1500
402
432
462
366
389
430
146
150
166
413
450
510
148
158
180
91
92
92
93
94
94
3718
4328
4530
4063
4673
4945
3458
4028
4210
54
54
53
32
47
53
4
4
4
2
3
4
6
7
8
17
13
11
6
7
8
27083
31597
36111
15.7
15.7
15.7
113
113
113
1000
1000
1000
1
1
1
80
80
80
400
400
400
6
6
6
168.3
168.3
168.3
5
5
5
139.7
139.7
139.7
522
465
192
560
201
92
94
4704
5119
4384
54
53
4
4
8
13
8
36111 Speed
113
1000
1
80
400
6
168.3
5
139.7