*override set to 1 FOR THIS ZONE only if one of commands *ZxxBASSyy<CR>,
*ZxxTREByy<CR>, *ZxxGRPq<CR>, or *ZxxVRSTr<CR> are issued (see descriptions
below).
Once it is SET by one of these commands:
a. It will remain set until power is cycled on the unit.
b. Non-address DIP switch changes on a connected KEYPAD connected to this zone
will be ignored.
If override state is "0", this response is also issued whenever non-address KEYPAD DIP switches
are changed.
*********************************************************************************
COMMAND:
*ZxxON<CR> – Turn zone xx ON.
RESPONSE:
Same response as for *ZxxCONSR<CR>
*********************************************************************************
COMMAND:
*ZxxOFF<CR> – Turn zone xx OFF.
RESPONSE:
Same response as for *ZxxCONSR<CR>
*********************************************************************************
COMMAND:
*ALLOFF<CR> – Turn ALL zones OFF.
RESPONSE:
#ALLOFF<CR>
This RESPONSE is also issued when ALL OFF is pressed on any KEYPAD.
*********************************************************************************
COMMAND:
*ALLV+<CR> – Ramp ALL zones UP at a 10 dB/second rate in 1 dB steps.
RESPONSE:
#ALLV+<CR>
The ramp action will be cancelled when all zones reach MAXIMUM volume, or when an
*ALLHLD<CR> Command is received. Note that to stop the ramp with this command before
maximum volume, one reference zone must be periodically polled with a *ZxxCONSR<CR>
Command to determine when the desired volume point has been reached. Note that ramps in
different zones may start at different levels and will all ramp at the same rate.
*********************************************************************************
COMMAND:
*ALLV-<CR> – Ramp ALL zones DOWN at a 10 dB/second rate in 1 dB steps.
RESPONSE:
#ALLV-<CR>
The ramp action will be cancelled when all zones reach MINIMUM (OFF) volume, or when an
*ALLHLD<CR> Command is received. Note that to stop the ramp with this command before the
minimum volume, one reference zone must be periodically polled with a *ZxxCONSR<CR>
Command to determine when the desired volume point has been reached. Note that ramps in
different zones may start at different levels and will all ramp at the same rate.
-yy = EQ level, dB, –8 to +0 (flat) to
+8 in 1 dB increments
-q = 0 if SOURCE GROUP is ON
1 if SOURCE GROUP is OFF
(This follows DIP switch definition.)
-r = 0 if VOLUME RESET is ON
1 if VOLUME RESET is OFF
(This follows DIP switch definition.)