Goodman Amana AMH8 Service Instructions Manual page 9

33 3/8" 80% modified two stage gas furnaces
Hide thumbs Also See for Amana AMH8:
Table of Contents

Advertisement

PRODUCT IDENTIFICATION
MODEL #
MFG #
AFE18-60A
N/A
P1221001
EFR01
P1221002F
FTK04
FTK04
HANG20
N/A
HANG21
N/A
N/A
HA02
Fossil Fuel Kit. The AFE18-60A control is designed for use where the indoor coil is located
above/downstream of a gas or fossil fuel furnace when used with a heat pump. It will operate with
single and two stage heat pumps and single and two stage furnaces. The AFE18-60A control will
turn the heat pump unit off when the furnace is turned on. An anti-short cycle feature initiates a 3
minute timed off delay when the compressor goes off.
External Filter Rack Kit . For use with Goodman® and Amana® Brand upflow furnaces. This kit
is intended to provide a location, external to the furnace casing, for installation of a permanent
filter. The rack is mounted over the indoor air blower compartment area of either side panel, and
provide filter retention as well as a location for attaching return air ductwork.
Furnace Twinning Kit . This kit allows Goodman® or Amana® Brand single stage 80% gas
furnaces to operate at the same time from a single thermostat. The two furnaces to be "twinned"
must be the exact same model with their circulating air blowers set to deliver the same air flow at
the same time. This kit cannot be used to control more than two furnaces.
High Altitude Natural Gas Kit. The kit is designed to convert 80% gas furnace models
fired at 20,000 Btu's per cell for higher altitudes. This kit is required when installing these
furnaces above their maximum rated altitude.
High Altitude Natural Gas Kit. The kit is designed to convert 80% gas furnace models
fired at 20,000 Btu's per cell for higher altitudes. This kit is required when installing these
furnaces above their maximum rated altitude.
High Altitude Natural Gas Kit. The kit is designed to convert Goodman®, Amana® Brand gas
furnace models fired at 22,500 BTU's per cell for higher altitudes. This kit is required when
installing these furnaces above their maximum rated altitude. This kit contains # 43-49, 55-58 gas
orifices. The orifices in the kit have been selected as a result of testing with the American Gas
Association. They will provide appropriate derating at the altitude listed in the High Altitude Charts
as shown in the installation instructions of the kit.
DESCRIPTION