Goodman Amana AMH8 Service Instructions Manual page 5

33 3/8" 80% modified two stage gas furnaces
Hide thumbs Also See for Amana AMH8:
Table of Contents

Advertisement

PRODUCT IDENTIFICATION
MODEL#
MFG.#
GDH80453A*
GDH80703A*
GDH8**CA
GDH80904B*
GDH81155C*
GDH80453A*
GDH80703A*
GDH8***CB
GDH80904B*
GDH81155C*
GDH80403A*
GDH80603A*
GDH8***AA
GDH80804B*
GDH81005C*
GDH80403A*
GDH80603A*
GDH8***BA
GDH80804B*
GDH81005C*
GDH80403A*
GDH80603A*
GDH8***BB
GDH80804B*
GDH81005C*
GDH80403B*
GDH8***BC
GDH80603B*
Goodman® Brand 80% Modified Two-Stage Gas Furnace , Dedicated down flow installation, 33
3/8" tall, Induced draft, Two stage gas Valve, Integrated circuit board controlling 2nd stage gas
valve by time. Left or right side gas entry. Aluminized steel heat exchanger. PSC blower motor.
115 volt silicon nitride igniter. "X" models are low NOx. Chassis sizes are 14", 17.5" and 21" wide.
Goodman® Brand 80% Modified Two-Stage Gas Furnace , Dedicated down flow installation, 33
3/8" tall, Induced draft, Two stage gas Valve, Integrated circuit board controlling 2nd stage gas
valve by time. Left or right side gas entry. Aluminized steel heat exchanger. PSC blower motor.
115 volt silicon nitride igniter. "X" models are low NOx. Chassis sizes are 14", 17.5" and 21" wide.
"CB" revisions went to a Honeywell gas valve.
Goodman® Brand 80% Modified Two-Stage Gas Furnace , New model nomenclature, fired at
23,000 BTUH per burner. Dedicated down flow installation, 33 3/8" tall, Induced draft, Two stage
gas Valve, Integrated circuit board controlling 2nd stage gas valve by time. Left or right side gas
entry. Aluminized steel heat exchanger. PSC blower motor. 115 volt silicon nitride igniter. "X"
models are low NOx. Chassis sizes are 14", 17.5" and 21" wide.
Goodman® Brand 80% Modified Two-Stage Gas Furnace , fired at 20,000 BTUH per burner.
Dedicated down flow installation, 33 3/8" tall, Induced draft, Two stage gas valve, Integrated circuit
board controlling 2nd stage gas valve by time. Left or right side gas entry. Aluminized steel heat
exchanger. PSC blower motor. 115 volt silicon nitride igniter. "X" models are low NOx. Chassis
sizes are 14", 17.5" and 21" wide. "BA" revisions have a standard rated altitude of 4,500 ft.
Goodman® Brand 80% Modified Two-Stage Gas Furnace , fired at 20,000 BTUH per burner.
Dedicated down flow installation, 33 3/8" tall, Induced draft, Two stage gas valve, Integrated circuit
board controlling 2nd stage gas valve by time. Left or right side gas entry. Aluminized steel heat
exchanger. PSC blower motor. 115 volt silicon nitride igniter. "X" models are low NOx. Chassis
sizes are 14", 17.5" and 21" wide. "BB" revisions have a standard rated altitude of 5,500 ft.
Goodman® Brand 80% Modified Two-Stage Gas Furnace , fired at 20,000 BTUH per burner.
Dedicated down flow installation, 33 3/8" tall, Induced draft, Two stage gas valve, Integrated circuit
board controlling 2nd stage gas valve by time. Left or right side gas entry. Aluminized steel heat
exchanger. PSC blower motor. 115 volt silicon nitride igniter. "X" models are low NOx. Chassis
size is 14" wide. "BC" revisions are equipped with a Broad Ocean motor.