Excell Dingo EX2002 User Manual page 69

Table of Contents

Advertisement

EXCELL PRECISION CO., LTD
Function Configuration Menu
Item
Function
SQ- 01
Batching mode
SQ- 02 Batching start delay time
SP1,SP2
SQ- 03
Waiting time comparison
Batch finish output signal
SQ- 04
delay time
SQ- 05
Batch finish Condition
Batch finish
SQ- 06
Output signal time
Batch finish signal
Number of Times the
SQ- 07
supplementary loading
function operates
Supplementary loading
SQ- 08
gate open time
Supplementary loading
SQ- 09
gate close time
Supplementary loading signal
ON
OFF
SQ- 07 Times of "ON" of the supplementary loading
04011010
Parameter
1
2
3
4
5
6
0.0 ~ 25.5
(sec)
0.0 ~ 25.5
(sec)
0.0 ~ 25.5
(sec)
0
1
0.0 ~ 25.5
(sec)
ON
SQ 04
OFF
Batch finish
0 ~ 255
0.0 ~ 25.5
(sec)
0.0 ~ 25.5
(sec)
SQ- 08
SQ- 09
Setting value
Description
Normal batch
Loss-in weight
Comparison mode
Normal batch (Built-in program)
Loss-in weight (Built-in program)
Hold mode (Built-in program)
The built-in auto-program starts the
batch comparison procedure after the
input of the batch start signal
No full flow comparison during this
function's set time period. If the set
value is 0, indicates this function is not
in use
Output the batch finished signal after
this delay time
Wait until the weight is stabilized
No need to wait until the weight has
stabilized
Batch finished output signal time.
If set to 0, the output signal will be off
until the next batch start
SQ 06
If the set value is 0, this function is
not in use
Must be coordinate with times of
supplementary loading, (SQ- 07)
Must be coordinate with times of
supplementary loading, (SQ- 07)
SQ- 09
67
Default
1
0.0
0.0
0.5
0
1.0
0
0.1
1.0
SQ- 08
ZSME400000002

Advertisement

Table of Contents
loading

Table of Contents